Catheter ablation of atrial fibrillation using FireMagic TrueForce ablation catheter: The TRUEFORCE trial

Author:

Zhang Rongfeng1ORCID,Chu Huimin2ORCID,Liu Shaowen3ORCID,Yang Bing4,Han Bing5ORCID,Xiao Xianjie1,Ma Chengming1,Sun Yuanjun1,Yin Xiaomeng1,Xia Yunlong1ORCID,Gao Lianjun1,

Affiliation:

1. Department of Cardiology Institute of Cardiovascular Diseases First Affiliated Hospital of Dalian Medical University Dalian China

2. Department of Cardiology Ningbo First Hospital Ningbo China

3. Department of Cardiology Shanghai General Hospital Shanghai China

4. Department of Cardiology Dongfang Hospital Affiliated to Tongji University Shanghai China

5. Department of Cardiology Xuzhou Central Hospital Xuzhou China

Abstract

AbstractBackgroundThe use of contact force (CF) sensing catheters has provided a revolutionary improvement in catheter ablation (CA) of atrial fibrillation (AF) in the past decade. However, the success rate of CA for AF remains limited, and some complications still occur.MethodsThe TRUEFORCE trial (Catheter Ablation of Atrial Fibrillation using FireMagic TrueForce Ablation Catheter) is a multicenter, prospective, single‐arm objective performance criteria study of AF patients who underwent their first CA procedure using FireMagic TrueForce ablation catheter.ResultsA total of 120 patients (118 with paroxysmal AF) were included in this study, and 112 patients included in the per‐protocol analysis. Pulmonary vein isolation (PVI) was achieved in 100% of the patients, with procedure and fluoroscopy time of 146.63 ± 40.51 min and 12.89 ± 5.59 min, respectively. Freedom from recurrent atrial arrhythmia after ablation was present 81.25% (95% confidence interval [CI]: 72.78%–88.00%) of patients. No severe adverse events (death, stroke/transient ischemic attack [TIA], esophageal fistula, myocardial infarction, thromboembolism, or pulmonary vein stenosis) were detected during the follow‐up. Four (4/115, 3.33%) adverse events were documented, including one abdominal discomfort, one femoral artery hematoma, one coughing up blood, and one postoperative palpitation and insomnia.ConclusionsThis study demonstrated the clinical feasibility of FireMagic force‐sensing ablation catheter in CA of AF, with a satisfactory short‐ and long‐term efficacy and safety.

Publisher

Wiley

Subject

Cardiology and Cardiovascular Medicine,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3