Accuracy of implant placement via dynamic navigation and autonomous robotic computer‐assisted implant surgery methods: A retrospective study

Author:

Zhang Sihui12,Cai Qin12ORCID,Chen Weiyi2,Lin Yuxuan2ORCID,Gao Yan12,Wu Dong12,Chen Jiang12

Affiliation:

1. Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Lab of Fujian College and University, School and Hospital of Stomatology Fujian Medical University Fujian PR China

2. Institute of Stomatology & Research Center of Dental and Craniofacial Implants, School and Hospital of Stomatology Fujian Medical University Fujian PR China

Abstract

AbstractObjectiveOptimal implant planning and placement allows the prosthesis to be well designed to achieve a satisfactory aesthetic and functional outcome. We aimed to compare deviations between implant planning and placement with the assistance of dynamic computer‐assisted implant surgery (d‐CAIS) or autonomous robotic computer‐assisted implant surgery (r‐CAIS) methods in a clinical setting.MethodsThe retrospective analysis of medical records between 2021 July and 2022 December was conducted to compare the implantation accuracy of the d‐CAIS and r‐CAIS system in partially edentulous patients through cone‐beam computed tomography. Patient‐reported outcomes (PROs) were recorded using a visual analogue scale (VAS). The Kolmogorov–Smirnov test was used to check the data distribution. Student's t‐test or Mann–Whitney U‐test was used as appropriate, with a defined significant difference (p < .05).ResultsSeventy‐seven patients were analysed (124 implants), with 38 patients (62 implants) in the d‐CAIS group and 39 patients (62 implants) in the r‐CAIS group. The differences between d‐CAIS and r‐CAIS were 4.09 ± 1.79° versus 1.37 ± 0.92° (p < .001) in angular deviation; 1.25 ± 0.54 versus 0.68 ± 0.36 mm (p < .001) in coronal global deviation; 1.39 ± 0.52 versus 0.69 ± 0.36 mm (p < .001) in apical global deviation; the results of the PROMs showed no statistical difference between the two groups.Conclusionsr‐CAIS allows more accurate implant placement than the d‐CAIS technology. And both groups achieved overall satisfactory outcomes via VAS (Chinese Clinical Trial Registry ChiCTR2300072004).

Publisher

Wiley

Subject

Oral Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3