Morphological and histological investigation of the conduction system in the equine atrial muscle sleeve of pulmonary veins

Author:

Kovacs Szilvia1,Racz Bence2ORCID,Sotonyi Peter2,Bakos Zoltan1

Affiliation:

1. Department and Clinic of Equine Medicine University of Veterinary Medicine Budapest Hungary

2. Department of Anatomy and Histology University of Veterinary Medicine Budapest Hungary

Abstract

AbstractBackgroundAtrial fibrillation is the most common arrhythmia in horses causing poor performance. The role of pulmonary vein triggers in the pathogenesis has been identified in horses. Ablation methods have been investigated, but the available information on anatomical, histological and immunohistochemical assessment of the pulmonary vein ostia and the conduction system of the myocardial sleeve is still limited.ObjectivesThe aim of the study was to describe the morphological properties of the myocardial sleeve in healthy horses.Study designCross‐sectional.MethodsEighty‐three equine hearts were dissected. The number and diameters of pulmonary vein ostia were determined, and anatomical localisation was described. Fifty‐eight tissue samples were collected for routine histology and 12 of these were used for immunohistochemistry (connexin 43, 45, S100, and tyrosine hydroxylase antibodies).ResultsThe mean number of pulmonary vein ostia was 4.5 (4 veins: 46 horse, 5 veins: 31 horses, 6 veins: 6 horses). Diameters (mean ± SD) of the main ostia were as follows: vein I: 20.2 ± 7.0 mm, vein II: 32.7 ± 7.1 mm, vein III: 33.4 ± 5.9 mm, vein IV: 18.1 ± 4.5 mm. Diameters of supernumerary vein ostia varied between 3.0 and 28.0 mm (11.5 ± 5.5 mm). Early branching was found in 26 horses (31.3%) and 30 veins (vein I: 14, vein II: 9, vein III: 5, vein IV: 2). Histology confirmed the presence of a muscle sleeve composed of myocardial tissue in each pulmonary vein. S100 and TH positivity was detected in each vein, and it confirmed the presence of adrenergic and non‐adrenergic nerve fibres within the myocardial sleeve. Cx43 and 45 positivity were also found in each vein indicating the presence of gap junctions.Main limitationsThe effect of bodyweight on pulmonary vein dimensions is unknown.ConclusionsFuture ablation techniques should consider that conductive tissue is present in the entire myocardial sleeve in all pulmonary vein ostia.

Publisher

Wiley

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3