Performance of the new MC‐80 automated digital cell morphology analyser in detection of normal and abnormal blood cells: Comparison with the CellaVision DM9600

Author:

Merino Anna1ORCID,Laguna Javier1ORCID,Rodríguez‐García María1,Julian Judit1,Casanova Alexandra1,Molina Angel1

Affiliation:

1. Haematology and Cytology Unit, CORE Laboratory. Biochemistry and Molecular Genetics Department, Biomedical Diagnostic Centre Hospital Clínic of Barcelona Barcelona Spain

Abstract

AbstractIntroductionMindray MC‐80 is an automated system for digital imaging of white blood cells (WBCs) and their pre‐classification. The objective of this work is to analyse its performance comparing it with the CellaVision® DM9600.MethodsA total of 445 samples were used, 194 normal and 251 abnormal: acute leukaemia (100), myelodysplastic syndromes/myeloproliferative neoplasms (33), lymphoid neoplasms (50), plasma cell neoplasms (14), infections (49) and thrombocytopenia (5). WBC pre‐classification values with the MC‐80 and DM9600 were compared with (1) the microscope, (2) Mindray BC‐6800Plus differentials in only normal samples, and (3) confirmed or reclassified images (post‐classification). Pearson's correlation, Lin's concordance, Passing‐Bablok regression, and Bland–Altman plots were used. Sensitivity, specificity, positive (PPV) and negative (NPV) predictive values for abnormal cells using the MC‐80 were calculated.ResultsThe PPV and NPV were above 98% and 99%, for normal samples. For immature granulocytes (IG), NPV and PPV were 100% and 74.2%. When comparing the WBC differentials using the MC‐80, the microscope and the BC‐6800Plus, no differences were found except for basophils and IG. Our results showed good agreement between the pre‐ and post‐classification of normal WBC, including IG, quantified by high correlation and concordance values (0.91–1). Sensitivity and specificity for blasts were 0.984 and 0.640. The MC‐80 detected abnormal lymphocytes in 30% of the smears from patients with lymphoid neoplasm. Plasma cell identification was better using the DM9600. The sensitivity and specificity for erythroblast detection were 1 and 0.890.ConclusionWe found that the MC‐80 shows high performance for WBC differentials for both normal samples and patients with haematological diseases.

Publisher

Wiley

Subject

Biochemistry (medical),Clinical Biochemistry,Hematology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3