Three‐dimensional transesophageal echocardiography measurements of ASD sizing parameters in comparison to balloon sizing method in percutaneous ASD closure

Author:

Narimani Sima12,Ayati Aryan1ORCID,Tayebi Amirhossein1,Jalai Arash1,Amirsardari Zahra1,Sahebjam Mohammad12,Zoroufian Arezou12

Affiliation:

1. Tehran Heart Center Cardiovascular Diseases Research Institute Tehran University of Medical Sciences Tehran Iran

2. Department of Advanced Echocardiography Tehran Heart Center Tehran University of Medical Sciences Tehran Iran

Abstract

AbstractBackgroundBalloon sizing (BS) has been used for device size selection in percutaneous atrial septal defect (ASD) closure. Due to its limitations, alternative imaging techniques like three‐dimensional transesophageal echocardiography (3D‐TEE) are valuable for guiding ASD device size selection during ASD closure procedures. The purpose of this study was to compare ASD sizing using measurements obtained from 3D–TEE to those utilizing the standard balloon sizing method.MethodsWe identified 53 patients with single secundum type ASD without PFO who underwent percutaneous closure at the Tehran Heart Center between 2019 and 2022. Balloon sizing was performed in all patients with the stop‐flow technique, and the choice of device size was determined based on the sizing derived from BS. 3D‐TEE imaging was performed before the intervention, and the ASD shape and quality of ASD rims were assessed.ResultsAmong the 53 patients who underwent single ASD device closure, multiple 3D TEE measurements significantly correlated with balloon sizing results. This included defect area, perimeter, and diameter obtained from 3D‐TEE images multi‐planar reconstruction. ASD perimeter detected by 3D TEE had the best correlation with BS results. When divided by the shape of ASD, there was no significant difference between our 3D‐images data and BS in round or oval‐shaped ASDs.ConclusionThe 3D‐TEE study is reliable for assessing ASD configurational characteristics in percutaneous device closure candidates. 3D‐TEE has the potential to accurately determine the appropriate device size and reduce complications, costs, and procedural duration. Further research is needed to validate these findings and establish the role of 3D‐TEE measurements in guiding the best treatment decisions for ASD closure.

Funder

Tehran Heart Center

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3