Performance of far forward iceless blood storage containers in controlled cold environments

Author:

Vuong Antoine12ORCID,Derkenne Clément23,Travers Stéphane24,Javaudin Olivier5ORCID,Clavier Benoît5,Martinaud Christophe2ORCID,Pasquier Pierre267

Affiliation:

1. Department of Anesthesiology and Intensive Care Bégin Military Training Hospital Saint‐Mandé France

2. French Military Medical Service Academy, École du Val‐de‐Grâce Paris France

3. French Military Health Service, 1e Antenne Médicale Spécialisée Versailles France

4. Paris Firefighters Brigade Paris France

5. French Military Blood Institute Clamart France

6. French Special Operations Forces Medical Command, Villacoublay France

7. Federation of Anesthesiology, Intensive Care Unit, Burns and Operating Theater, Percy Military Training Hospital Clamart France

Abstract

AbstractBackgroundThe Golden Hour Box (GHB), an iceless blood container designed for transfusion closest to the point of injury, is used by military medical teams in remote damage control resuscitation. While its performance is well‐established in hot environments, it remains underexplored in cold conditions, a significant consideration in emerging global conflict zones.Study Design and MethodsFour GHBs were preconditioned at +4°C or +18°C for 8 h and subsequently exposed to controlled laboratory simulated temperatures of −5, −15, and −25°C for 100 h. The study focused on their capability to maintain an internal temperature between +2 and +6°C, the recommended range for red blood cells unit storage and transport, using calibrated sensors for precise monitoring.ResultsWhen exposed to negative Celsius temperatures, GHBs showed varied performance depending on preconditioning temperatures. When preconditioned at +4°C, GHBs maintained an internal temperature within the target range (+2 to +6°C) for 100 h at −5°C, 52 ± 1 h at −15°C, and 29 ± 4 h at −25°C. In contrast, the internal temperature of GHBs preconditioned at +18°C exceeded this range in less than 30 min, then dropped below 2°C more rapidly than those preconditioned at +4°C, occurring within 20 ± 2 h at −15 and 13 ± 1 h at −25°C.ConclusionThe GHB, when properly preconditioned, effectively maintains internal temperatures suitable for blood product transport in extreme cold. Future research, including analyses of blood performances, is still needed to validate these results in more realistic operational conditions for use in cold environments.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3