The Effect of Placement Accuracy of Customized Titanium Mesh on Bone Regeneration: A Retrospective Study

Author:

Cheng Yi12ORCID,Chen Gang2ORCID,Wang Chao3ORCID,Chen Dan3ORCID,Zhao Pengyu2ORCID,Huang Haitao2ORCID

Affiliation:

1. Xinxiang Central Hospital Xinxiang Henan Province China

2. The First Affiliated Hospital of Dalian Medical University Dalian Liaoning Province China

3. Key Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, School of Engineering Medicine, State Key Laboratory of Virtual Reality Technology and Systems Beihang University Beijing China

Abstract

ABSTRACTObjectiveThis study aimed to evaluate the accuracy of three‐dimensional printed individualised titanium mesh (3D‐PITM) placement in protected bone regeneration surgery for alveolar bone defects.Material and MethodsThis study included 15 patients with alveolar bone defects who underwent protected bone regeneration surgery using 3D‐PITM as a scaffold. The 3D‐PITM was removed 6–9 months post‐bone regeneration surgery. Cone‐beam computed tomography (CBCT) data allowed for digital comparison between the actual titanium mesh and the preoperative design, analyzing the overall deviation and deformation angle of the titanium mesh. Additionally, morphology modification of the augmented areas was analyzed, and the volume was calculated.ResultsThe deviation of the titanium mesh immediately post‐bone regeneration surgery from the preoperative design was 0.93 ± 0.22 mm. The maximum deformation angle of the titanium mesh immediately post‐bone regeneration surgery was 21.49°, averaging 10.85° ± 6.70°. Correlation analysis indicated that a larger deformation angle post‐bone regeneration surgery resulted in a greater deviation from the preoperative titanium mesh design. With one failure case excluded, the average actual bone augmentation achieved was 92.83% ± 26.12% of the design. Due to the small sample size, no significant correlation was found between the actual percentage of bone fill and the Root Mean Square (RMS) deviation and deformation angle of the titanium mesh.ConclusionAlthough 3D‐PITM‐protected bone regeneration provided effective bone augmentation, a noticeable deviation remained between the titanium mesh's actual position and preoperative design. However, due to the small sample size, there was a non‐significant correlation between the actual percentage of bone fill volume and the RMS deviation and deformation angle of the titanium mesh.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.7亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2025 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3