Daily change of peritoneal ultrafiltration volume in patients with hybrid dialysis

Author:

Toda Naohiro12ORCID,Komiya Toshiyuki1,Ishii Akira1,Mori Keita P.3,Sugitani Seita4,Yanagita Motoko56,Yokoi Hideki5

Affiliation:

1. Department of Nephrology Kansai Electric Power Hospital Osaka Japan

2. Division of Renal Disease and Blood Purification Kansai Electric Power Medical Research Institute Kobe Japan

3. Department of Nephrology and Dialysis Medical Research Institute Kitano Hospital, PIIF Tazuke‐Kofukai Osaka Japan

4. Department of Nephrology Japanese Red Cross Society Wakayama Medical Center Wakayama Japan

5. Department of Nephrology Graduate School of Medicine, Kyoto University Kyoto Japan

6. Institute for the Advanced Study of Human Biology (WPI‐ASHBi) Kyoto University Kyoto Japan

Abstract

AbstractIntroductionHybrid dialysis is widely used in Japan. Although previous reports have shown the beneficial effects of hybrid dialysis, little is known about the daily change in peritoneal ultrafiltration volume in hybrid dialysis.MethodsA multicenter, cross‐sectional study was conducted in 25 patients with hybrid dialysis. The primary outcome measure was the change in peritoneal ultrafiltration volume between after HD and before HD, according to PD prescription and PD holiday. The secondary outcome measure was the correlation between the difference in ultrafiltration volume and each factor.ResultsThe total ultrafiltration volume and the ultrafiltration volume of glucose dialysate after HD increased from 970 ± 408 to 1151 ± 480 (p < 0.01) and from 576 ± 392 to 750 ± 517 (p < 0.01), respectively, compared with before HD. In contrast, the ultrafiltration volume of icodextrin dialysate did not change (from 470 ± 204 to 494 ± 242, p = 0.40). The difference in total ultrafiltration volume was correlated with the difference in glucose dialysate ultrafiltration volume and hybrid duration, but not with the difference in icodextrin dialysate ultrafiltration volume and peritoneal dialysis duration.ConclusionThis study showed that the peritoneal ultrafiltration volume for glucose dialysate increased after HD compared with before HD in patients with hybrid dialysis, whereas that for icodextrin dialysate did not change.

Funder

Osaka Kidney Foundation

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司