Author:
PETERSEN HELEN HØGH,CHEN XU,PIETERSEN ADRIAN,SVENDSEN JESPER HASTRUP,HAUNSØ STIG
Abstract
The limited success rate of radiofrequency catheter ablation in patients with ventricular tachycardias related to structural heart disease may be increased by enlarging the lesion size. Irrigated tip catheter ablation is a new method for enlarging the size of the lesion. It was introduced in the power‐controlled mode with high power and high infusion rate, and is associated with an increased risk of crater formation, which is related to high tissue temperatures. The present study explored the tissue temperatures during temperature‐controlled irrigated tip ablation, comparing it with standard temperature‐controlled ablation and power‐controlled irrigated tip ablation. In vitro strips of porcine left ventricular myocardium were ablated. Temperature‐controlled irrigated tip ablation at target temperatures 60°C, 70°C, and 80°C with infusion of 1 mL saline/min were compared with standard temperature‐controlled ablation at 70°C and power‐controlled irrigated tip ablation at 40 W, and infusion of 20 mL/min. Lesion size and tissue temperatures were significantly higher during all modes of irrigated tip ablation compared with standard temperature‐controlled ablation (P < 0.05). Lesion volume correlated positively with tissue temperature (r = 0.87). The maximum recorded tissue temperature was always 1 mm from the ablation electrode and was 67 ± 4°C for standard ablation and 93 ± 6°C, 99 ± 6°C, and 115 ± 13°C for temperature‐controlled irrigated tip ablation at 60°C, 70°C, and 80°C, respectively, and 112 ± 12°C for power‐controlled irrigated tip ablation, which for irrigated tip ablation was significantly higher than tip temperature (P < 0.0001). Crater formation only occurred at tissue temperatures > 100°C. We conclude that irrigated tip catheter ablation increases lesion size and tissue temperatures compared with standard ablation in the temperature‐controlled mode at the same or higher target temperatures and in the power‐controlled mode. Furthermore, tissue temperature and delivered power are the best indicators of lesion volume during temperature‐controlled ablation.
Reference19 articles.
1. Comparison of In Vivo Tissue Temperature Profile and Lesion Geometry for Radiofrequency Ablation With a Saline-Irrigated Electrode Versus Temperature Control in a Canine Thigh Muscle Preparation
2. Myocardial healing patterns during radiofrequency energy delivery via an irrigated electrode;Demazumder DBS;PACE,1997
3. Comparison of different electrodes for radiofrequency ablation of myocardium using saline “irrigation”;Demazumdfir DBS;PACE,1997
4. Impact of ablation location on impedance pop occurrence with irrigated tip energy delivery in dogs;Packer DL;PACE,1997
5. Radiofrequency catheter ablation of ventricular myocardium using a cooled catheter system;Dorwarth U;Eur Heart f,1996
Cited by
92 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献