Safety and feasibility of stereotactic radiotherapy using computed portal radiography for canine intracranial tumors

Author:

Rancilio Nicholas J.1ORCID,Bentley R. Timothy1,Plantenga Jeannie Poulson1,Parys Magdalena M.1,Crespo Beatriz G.1,Moore George E.2

Affiliation:

1. Departments of Veterinary Clinical Sciences, College of Veterinary Medicine Purdue University West Lafayette IN USA

2. Veterinary Administration, College of Veterinary Medicine Purdue University West Lafayette IN USA

Abstract

AbstractStereotactic radiotherapy is a highly conformal treatment option for intracranial and extracranial malignancies. Stereotactic radiotherapy utilizes specialized equipment specifically designed to avoid normal tissue while delivering ablative treatments with submillimeter precision and accuracy. Linear accelerator based stereotactic radiotherapy incorporates on‐board image guidance utilizing cone beam computed tomography (CT). Many institutions lack the ability to provide image guidance with cone beam CT but delivery of highly conformal treatments with submillimeter precision and accuracy is still feasible. The purpose of this retrospective, pilot study was to describe clinical outcomes for a group of dogs with neurological disease that were treated with an stereotactic radiotherapy technique utilizing intensity modulated radiation therapy, megavoltage computed portal radiography, a bite plate, thermoplastic mold, and mask based positioning system. Twelve dogs with neurological clinical signs were included. The diagnosis of intracranial tumor was made based on advanced imaging (12/12) and confirmed via histopathology (3/12). Twelve courses of stereotactic radiotherapy, utilizing three fractions of 8.0 Gy, were delivered on alternating days. Self‐resolving neurological deterioration was observed in two patients during stereotactic radiotherapy. Neurological progression free interval and median survival time were 273 days (range: 16–692 days) and 361 days (range: 25–862 days). Stereotactic radiotherapy using computed portal radiography may be a safe treatment option for dogs with intracranial tumors.

Publisher

Wiley

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.7亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2025 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3