Use of a novel indentometer to evaluate skin stiffness in healthy and diseased human skin

Author:

Ivanova Zlatina1,Aleksiev Teodor1,Dobrev Hristo1ORCID,Atanasov Nikolay2

Affiliation:

1. Department of Dermatology and Venereology, Medical Faculty Medical University Plovdiv Bulgaria

2. Department of Health Management and Health Economics, Faculty of Public Health Medical University Plovdiv Bulgaria

Abstract

AbstractBackgroundMechanical behavior of the skin can be evaluated by different non‐invasive methods. In this study, we applied a new measurement device based on indentometry to determine the skin mechanical properties in healthy individuals and in patients with systemic sclerosis (SSc).Material and methodsThree studies were performed. Study 1 included 100 healthy individuals (46 male and 54 female) divided into four age groups with mean ages of 21.5, 28.9, 51.2, and 69.3 years, respectively. Test sites were located on the center of the forehead and the middle of both volar forearms. Study 2 included 16 healthy individuals (two males and 14 females). Test sites were on both volar forearms. Measurements were made before and after the application of Vaseline and emulsion with 12% urea. Study 3 included 20 patients (one male and 19 females) with SSc and 60 age‐matched healthy individuals (23 males and 37 females). Test sites were on the center of the forehead and the middle of both volar forearms. Skin stiffness was measured with skin Indentometer IDM 800 (Courage + Khazaka, Cologne, Germany) equipped with two probes with pin diameters of 3 and 5 mm, respectively. The stiffer the skin, the less deep the displacement by the indenter. The smaller the diameter, the deeper the pin will go into the skin when using the same force. In addition, the Corneometer CM 820 (Courage + Khazaka) was used to determine epidermal water content in study 2.ResultsIndentometric (IDM) values of healthy subjects measured with both probes were lower on the forehead compared to volar forearms. There was no significant difference between both forearms. In all age groups, the IDM values on the male forearms were lower than on the female forearms whereas there was no significant difference on the forehead. In both sex and on all test locations a significant positive correlation between age and IDM values measured with both probes was observed. There was a significant positive correlation between IDM values measured with both probes. The application of moisturizers induced significant changes in epidermal water content whereas the IDM values remained unchanged. At both the forehead and volar forearms, the IDM values in patients with SSc were significantly lower compared to the healthy control skin.ConclusionThe non‐invasive indentometric method used can successfully distinguish the changes in normal skin mechanical properties related to age, sex, and anatomical location, as well as in patients with SSc. The method is not appropriate to study the changes related to epidermal hydration.

Publisher

Wiley

Subject

Dermatology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3