Effects of sterilization, conditioning, and thermal aging on the retention of zirconia hybrid abutments: A laboratory study

Author:

Alghanaim Nalah12ORCID,Kern Matthias1ORCID,Yazigi Christine1ORCID,Chaar M. Sad1ORCID

Affiliation:

1. Department of Prosthodontics, Propaedeutics and Dental Materials, School of Dentistry Christian‐Albrechts University Kiel Germany

2. Department of Prosthodontics, Faculty of Dentistry King Abdulaziz University Jeddah Saudi Arabia

Abstract

AbstractObjectiveTo investigate the effects of sterilization, conditioning method, and thermal aging on the retentive strength of two‐piece zirconia abutments.Materials and MethodsIn total, 128 stock zirconia abutments were divided into four groups (n = 32) according to the conditioning parameters: (A) air‐abrasion using 50 μm alumina particles/1.0 bar, (B) 50 μm/2.0 bar, (C) 100 μm/1.0 bar, and (D) 100 μm/2.0 bar. All abutments were bonded onto titanium bases using DTK adhesive resin and stored in water bath (37°C) for 72 h. Each group was subdivided into two subgroups (n = 16), group 1 was disinfected, whereas group 2 followed disinfection and autoclave sterilization. Half of the specimens of each subgroup (n&amp;#x02009;=&amp;#x02009;8) was directly subjected to the axial retention test (groups N), while the other half was first subjected to 150&amp;#x02009;days of thermocycling followed by retention test (groups T). Statistical analysis was performed with three‐way ANOVA, additional statistical analysis was performed by using separate one‐way ANOVAs followed by the Tukey's post‐hoc test for post hoc pairwise comparisons among groups.ResultsThe highest median retention strength was recorded for group B2N (1390 N), whereas the lowest strength was recorded for group C1T (688 N). No significant interaction (p ≥ 0.05) was detected between the different variables; conditioning method, sterilization, and the thermal cycling regarding the effect on the resulting retention. However, the sterilization always showed a positive effect. Thermocycling presented an adversely significant effect only in the absence of sterilization (p < 0.05), with the exception of subgroups A. For the sterilized groups, thermocycling had no statistically significant effect on the retention.ConclusionSteam autoclaving increased the retention of hybrid zirconia abutments. DTK adhesive resin for two‐piece zirconia abutments performed well after sterilization and thermocycling.

Publisher

Wiley

Reference38 articles.

1. Outcome analysis of implant restorations located in the anterior maxilla: a review of the recent literature;Belser UC;Int J Oral Maxillofac Implant.,2004

2. Retentive Strength of Two-Piece CAD/CAM Zirconia Implant Abutments

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3