Evaluation of the trueness and precision of conventional impressions versus digital scans for the all‐on‐four treatment in the maxillary arch: An in vitro study

Author:

Marshaha Nour Jamal1ORCID,Azhari Amr Ahmed2ORCID,Assery Mansour K3ORCID,Ahmed Walaa Magdy2ORCID

Affiliation:

1. Graduate Prosthodontics, Prosthodontics, Faculty of Dentistry Riyadh Elm University Riyadh Saudi Arabia

2. Department of Restorative Dentistry, Faculty of Dentistry King Abdulaziz University Jeddah Saudi Arabia

3. Department of Prosthodontics, College of Dentistry Riyadh Elm University Riyadh Saudi Arabia

Abstract

AbstractPurposeTo compare the accuracy of digitizing conventional impressions to intraoral surface scans for all‐on‐four treatment in the maxillary arch.Materials and methodsAn edentulous maxillary arch model with four implants placed in an all‐on‐four design was fabricated. Intraoral surface scans (n = 10) were obtained using an intraoral scanner after scan body insertion. For conventional polyvinylsiloxane impressions of the model, implant copings were inserted into the implant fixation for implant level, opened tray impressions (n = 10). The model and conventional impressions were digitized to obtain digital files. A reference file was created using a laboratory‐scanned conventional standard tessellation language (STL) file with analog to scan the body using exocad software. STL datasets from the two digital and conventional impression groups were superimposed with reference files to assess the 3D deviations. Two‐way ANOVA and paired‐samples t‐test was performed to assess the difference in trueness and examine the effects of impression technique and implant angulation on the deviation amount.ResultsNo significant differences were found between the conventional impression and intraoral surface scan groups F(1, 76) = 2.705, p = 0.104. No significant differences were found between conventional straight and digital straight implants and between conventional and digital tilted implants F(1, 76) = .041, p = 0.841. No significant differences were found between conventional straight and conventional tilted implants p = 0.07 and between digital straight and digital tilted implants p = 0.08.ConclusionDigital scans were more accurate than conventional impressions. The digital straight implants were more accurate than the conventional straight implants, and the digital tilted implants were more accurate than the conventional tilted implants, with higher accuracy for digital straight implants.

Publisher

Wiley

Subject

General Dentistry

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3