Fracture resistance and failure mode of endodontically treated premolars reconstructed by different preparation approaches: Cervical margin relocation and crown lengthening with complete and partial ferrule with three different post and core systems

Author:

Falahchai Mehran1ORCID,Musapoor Naghmeh2ORCID,Mokhtari Soroosh1,Babaee Hemmati Yasamin3,Neshandar Asli Hamid1ORCID

Affiliation:

1. Department of Prosthodontics School of Dentistry Guilan University of Medical Sciences Rasht Iran

2. Department of Prosthodontics School of Dentistry Qazvin University of Medical Sciences Qazvin Iran

3. Department of Orthodontics School of Dentistry Guilan University of Medical Sciences Rasht Iran

Abstract

AbstractPurposeTo assess the fracture resistance and failure mode of endodontically treated premolars reconstructed by different preparation approaches: cervical margin relocation (CMR) and crown lengthening (CL) with complete ferrule (CLF) and partial ferrule (CLPF) with three different post and core systems.Materials and MethodsIn this in vitro study, 100 maxillary premolars were assigned to the following 10 groups according to their preparation approach and type of post and core system (n = 10): (I) control (intact teeth), (II) prefabricated fiber post (PFP) and composite core with CMR (PFP‐CMR), (III) polyethylene fiber‐reinforced composite (PEFRC) with CMR (PEFRC‐CMR), (IV) casting post (CP) and core with CMR (CP‐CMR), (V) PFP‐CLPF, (VI) PEFRC‐CLPF, (VII) CP‐CLPF, (VIII) PFP‐CLF, (IX) PEFRC‐CLF, and (X) CP‐CLF. After thermomechanical loading, the fracture resistance and failure mode were assessed. Data were analyzed statistically (α = 0.05).ResultsIn all post and core systems, the CLPF approach had lower fracture resistance than CMR (p < 0.05); CLF showed higher fracture resistance than CLPF only in the PFP system (p = 0.038). In PEFRC and CP systems, the difference between CLF and CLPF was not significant (p > 0.05). No significant difference was found in fracture resistance of different post and core systems with the same preparation approach (p > 0.05). CLPF showed the highest frequency of favorable, and CLF showed the highest frequency of unfavorable fractures.ConclusionCLPF yielded lower fracture resistance than CMR. The difference in fracture resistance was not significant between CLF and CMR but the frequency of unfavorable fractures was higher in CLF than in other groups.

Publisher

Wiley

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3