Anatomic evaluation of the normal variants of the arteries of face using color Doppler ultrasonography: Implications for facial aesthetic procedures

Author:

Khorasanizadeh Faezeh12ORCID,Delazar Sina1ORCID,Gheidari Omid3,Daneshpazhooh Maryam3,Balighi Kamran3,Ehsani Amir Houshang3,Emadi Seyed Nasser3,Sadeghinia Ali3,Mahmoudi Hamidreza3ORCID

Affiliation:

1. Advanced Diagnostic and Interventional Radiology Research Center (ADIR) Tehran University of Medical Sciences Tehran Iran

2. Department of Radiology Razi Hospital, Tehran University of Medical Sciences Tehran Iran

3. Autoimmune Bullous Diseases Research Center, Department of Dermatology Razi Hospital, Tehran University of Medical Sciences Tehran Iran

Abstract

AbstractBackgroundKnowledge of normal facial vascular variations could prevent catastrophic complications of cosmetic procedures as well as providing a guide for surgical planning. Color Doppler ultrasound is a safe and noninvasive method for real time vascular evaluation.ObjectiveThe aim of this study was to evaluate the normal variations of the facial, angular, transverse facial, supratrochlear and supraorbital arteries in a sample of normal individuals.MethodsNormal individuals referred for dermal filler injection to the tertiary dermatologic center, were selected. Patients who were smoker or had a history of facial filler injection, facial surgery, or trauma were excluded from the study. Facial artery at three levels as well as angular, supratrochlear, supraorbital, and transverse facial arteries were evaluated by an 18 MHz ultrasound linear probe regarding their distance from facial reference lines and landmarks, and also their depths in various regions of face.ResultsA total number of 43 individuals were evaluated in this study. Thirty‐one (72.1%) were women. The number of absent facial artery was zero in level one, three (3.48%) in level two, and nine (10.46%) in level three. The angular artery was absent in 10 (11.62%) participants. The transverse facial artery was absent in 27 (31.39%) assessed individuals. Distance from reference lines at level 2 and 3 of facial artery and its depth at level 2 were significantly different between left and right side (p‐values: <0.001, 0.01, and 0.03, respectively). No significant difference was seen between depth and distance of two sides for angular and transverse facial arteries. The comparison of the depths and distances from the reference lines of the assessed arteries between two sexes revealed only a significantly greater value of facial artery distance in level 1 in males (p‐value: 0.001). BMI was also significantly correlated with the depth of facial artery in level 2 (Pearson correlation coefficient = 0.471, p‐value = 0.002) and level 3 (Pearson correlation coefficient = 0.357, p‐value = 0.03) and the distance of the facial artery in level 1 (Pearson correlation coefficient = 0.333, p‐value = 0.029).ConclusionsColor Doppler ultrasound could be used to map the arteries of face to prevent vascular complications and safely guide cosmetic procedures.

Publisher

Wiley

Subject

Dermatology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3