Retrospective evaluation of fresh platelet concentrate administration in dogs: Patient characteristics, outcomes, and transfusion practices in 189 transfusion episodes (2008–2019)

Author:

Saint‐Pierre Laurence M.1ORCID,Farrell Kate S.2ORCID,Hopper Kate2,Reagan Krystle L.3ORCID

Affiliation:

1. William R. Pritchard Veterinary Medical Teaching Hospital University of California Davis California USA

2. Department of Veterinary Surgical and Radiological Sciences University of California Davis California USA

3. Department of Medicine & Epidemiology, School of Veterinary Medicine University of California Davis California USA

Abstract

AbstractObjectiveTo describe patient characteristics, underlying disease processes, clinical outcomes, transfusion dose and type (therapeutic or prophylactic), platelet count changes, and adverse events associated with platelet concentrate (PC) administration in dogs.DesignRetrospective study.SettingUniversity teaching hospital.AnimalsA total of 149 dogs, representing 189 PC transfusion episodes.InterventionsNone.Measurements and Main ResultsIn this population, 39 of 149 dogs (26.2%) were diagnosed with primary immune‐mediated thrombocytopenia, 22 of 149 (14.8%) had decreased bone marrow production, 12 of 149 (8.0%) received PC during a massive transfusion, 3 of 149 (2.0%) had congenital thrombocytopathia, 59 of 149 (39.6%) had severe thrombocytopenia of other causes, and 14 of 149 (9.4%) underwent transfusion for miscellaneous causes without a documented severe thrombocytopenia. In 117 of 149 dogs (78.5%), >1 site of hemorrhage was noted. The most common sites of hemorrhage were the gastrointestinal (GI) tract in 89 of 149 (59.7%) and the skin in 78 of 149 (52.3%). Overall survival to discharge was 59.1% (88/149). The median PC dose was 0.8 units per 10 kg of body weight per transfusion episode (range: 0.2–6.7). Of 189 episodes, 29 of 189 (15.7%) were prophylactic, and 158 of 189 (83.6%) were therapeutic. For 99 of 189 transfusion episodes, paired pre‐ and postplatelet counts were available within 24 hours. The median platelet count change was 5.0 × 109/L (5000/μL; range: –115 × 109/L to 158 × 109/L [–115,000 to 158,000/μL]); the posttransfusion platelet count was significantly higher than pretransfusion (P < 0.0001). The increase in platelet count after transfusion was greater in the prophylactic group than the therapeutic group (P = 0.0167). Transfusion reactions were suspected during 2 of 168 episodes (1.2%).ConclusionsImmune‐mediated thrombocytopenia was the most common disease process that resulted in PC transfusion. PC was more frequently administered to animals with active hemorrhage rather than prophylactically, and most dogs had evidence of hemorrhage in multiple organ systems, particularly the GI tract and skin. PC transfusions typically appeared safe, and the median platelet count increased after transfusion.

Publisher

Wiley

Subject

General Veterinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3