Spine Surgery with Electronic Conductivity Device: A Prospectively Multicenter Randomized Clinical Trial and Literature Review

Author:

Zhai Xiao1ORCID,Li Bo1ORCID,Chen Kai1,Chen Ziqiang1,Shao Jie1,Chen Kai1,Xu Qintong2,Meng Dehua2,Fei Qinming2,Jiang Leisheng3,Bai Yushu1,Li Ming1

Affiliation:

1. Department of Orthopaedics, Shanghai Changhai Hospital Navy Medical University Shanghai China

2. Department of Orthopaedic Surgery, Zhongshan Hospital Fudan University Shanghai China

3. Spine Center, Xinhua Hospital Shanghai Jiaotong University School of Medicine Shanghai China

Abstract

ObjectiveImproving accuracy and safety of pedicle screw placement is of great clinical importance. Electronic conductivity device (ECD) can be a promising technique with features of affordability, portability, and real‐time detection capabilities. This study aimed to validate the safety and effectiveness of a modified ECD.MethodsThe ECD underwent a modification where six lamps of various colors, and it was utilized in a prospectively multicenter randomized controlled clinical trial involving 96 patients across three hospitals from June 2018 to December 2018. The trial incorporated a self‐control randomization with an equal distribution of left or right side of vertebral pedicle among two groups: the free‐hand group and the ECD group. A total of 496 pedicle screws were inserted, with 248 inserted in each group. The primary outcomes focused on the accuracy of pedicle screw placement and the frequency of intraoperative X‐rays. Meanwhile, the secondary indicator measured the time required for pedicle screw placement. Results were presented as means ± SD. Paired samples t‐test and χ2‐test were used for comparison. Furthermore, an updated review was conducted, which included studies published from 2006 onwards.ResultsBaseline patient characteristics were recorded. The primary accuracy outcome revealed a 96.77% accuracy rate in the ECD group, compared to a 95.16% accuracy rate in the free‐hand group, with no significant differences noted. In contrast, ECD demonstrated a significant reduction in radiation exposure frequency when compared to the free‐hand group (1.11 ± 0.32 vs. 1.30 ± 0.53; p < 0.001), resulting in a 14.6% reduction. Moreover, ECD displayed a decrease of 30.38% in insertion time (70.88 ± 30.51 vs. 101.82 ± 54.00 s; p < 0.001). According to the results of the 21 studies, ECD has been utilized in various areas of the spine such as the atlas, thoracic and lumbar spine, as well as sacral 2‐alar‐iliac. The accuracy of ECD ranged from 85% to 100%.ConclusionThe prospectively randomized trial and the review indicate that the use of ECD presents a secure and precise approach to the placement of pedicle screws, with the added benefit of reducing both procedure time and radiation exposure.

Funder

National Natural Science Foundation of China

Publisher

Wiley

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3