Comparison of the Accuracy and Reliability of Instrumental Shade Selection Devices and Visual Shade Selection: An in Vitro Study

Author:

Kutkut N.1,Jordi M.2,Almalki A.3ORCID,Conejo J.1ORCID,Anadioti E.1,Blatz M.1ORCID

Affiliation:

1. Department of Preventive and Restorative Dentistry University of Pennsylvania Philadelphia Pennsylvania USA

2. Department of Restorative Dentistry University of Siena and Marseille University Siena Italy

3. Department of Prosthetic Dental Sciences Prince Sattam bin Abdulaziz University Al‐Kharj Saudi Arabia

Abstract

ABSTRACTObjectiveNew shade‐matching devices are available for clinical use, but their accuracy and reliability have not been investigated. This in vitro study compared the accuracy and reliability of a shade‐matching colorimeter (Optishade), a spectrophotometer (VITA Easyshade V), and visual shade matching in simulated clinical conditions.Material and MethodsShade matching was conducted with two digital devices; (Optishade and Vita Easyshade) and the visual shade selection method, with a new 16‐tab Vita Classical shade guide. Shade tabs were placed within a gingival matrix and measurements were taken from the central area of each shade tab enclosed in a black box to simulate the oral cavity. Visual assessments were conducted independently by two examiners. For the reliability assessment, each shade tab was measured 20 times by each examiner. Accuracy was calculated as a percentage of the matching readings with the actual shade per each tab. Data were analyzed with the one‐way ANOVA test (α = 0.05) and Pairwise Comparison (Bonferroni Post hoc Test) to assess accuracy. The reliability evaluation was conducted by comparison between both examiners using mean and standard deviation; by a two‐tailed t‐test for the independent samples for all the three groups included in the study.ResultThe shade matching accuracy of Optishade was 97.50%, Vita Easyshade 89.38%, and visual method 62.19%. Statistically, high significant difference in accuracy (p < 0.001) was found when comparing both Optishade and VITA Easyshade with the visual method. Additionally, there was statistically significant difference in accuracy (p < 0.05) when Optishade was compared to Vita Easyshade. The reliability of the Optishade was 99.6% and Vita Easy shade was 99.38%. Statistically, showed no statistically significant difference in the reliability of shade match obtained within the same group when comparing the readings of Examiner 1 and Examiner 2 (p > 0.05).ConclusionThe colorimeter demonstrated the highest accuracy, followed by the spectrophotometer, and the visual shade selection method. Both digital methods investigated in this study showed comparable reliability.Clinical ImplicationThe results of this study emphasize the clinical advantage of digital shade‐matching devices over visual shade‐matching. The colorimeter offers high accuracy for shade matching and should be considered to use for shade matching especially with restorations in the esthetic zone.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3