Energy, exergy analysis and optimization of insulation thickness on buildings in a low-temperature district heating system

Author:

TERHAN Meryem1ORCID,ABAK Sena Saliha2ORCID

Affiliation:

1. Department of Mechanical Engineering, Gumushane University, Gumushane, 29100, Türkiye

2. Department of Mechanical Engineering, Kafkas University, Kars, 36000, Türkiye

Abstract

In the study, energy and exergy analysis of the buildings on a campus in Turkey are conducted by using actual operating data and taking measurements in the district heating system as a case study. The energy and exergy demands, losses that stem from all buildings are calculated according to average daily outdoor temperature data. Due to the high heat losses in the buildings, determining the optimal insulation thickness for the exterior wall should be investigated. Therefore, optimal insulation thicknesses, energy savings, fuel consumptions and payback periods of the insulation material on the exterior wall of the building are examined by using Life Cycle Assessment and P1–P2 method for natural gas. Optimal insulation thicknesses are calculated for different insulation materials such as XPS, glass wool, rock wool and EPS for the climatic regions (HDD=800–4250°C days). According to average exergy losses from the building components per unit area, the average total exergy loss is calculated as 2.39×10-2 kW/m2.year and 1.42×10-3 kW/m2 (5.92%) of this loss stems from the exterior walls, 1.93×10-3 kW/m2 (8.07%) from the floors, 7.37×10-4 kW/m2 (3.08%) from the roofs, 1.58×10-2 kW/m2 (65.99%) from the windows and doors, 4.04×10-3 kW/m2 (16.92%) from the ventilation with infiltration. Energy requirement values of the building are found between 2.68–25.70 kWh/m3 towards from the warmest to the coldest climatic region for the uninsulated wall. In the un-insulated state, fuel consumption varies between 1.93-18.48 m3/m2 from the warmest to the coldest region. The optimal insulation thickness values of the building’s exterior wall are calculated as between 2.3–10.0 cm according to different climatic regions. In-state of exterior wall insulation of 3 cm, fuel consumption decreases by 46.63%–53.46% compared to different insulation materials and climatic regions compared to the un-insulated state.

Publisher

Journal of Thermal Engineering

Subject

Fluid Flow and Transfer Processes,Energy Engineering and Power Technology,Building and Construction

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370