With the development of minimally invasive treatment technology, coronary stents made of corrosion-resistant steel are in demand for restoring the patency of blood vessels. The effectiveness of coronary stenting depends on various factors, but the quality of the surface of the stents is a major factor. The higher the quality of the surface of the stent is, the less negative the effect on the circulatory system, arterial walls, and the higher the biocompatibility of the stent is. The complex shape, small cross-section, size, and low rigidity of coronary stents are the main reasons for the inability to ensure high surface quality using mechanical finishing methods. Therefore, electrochemical methods are used to polish stents. For electrochemical polishing (ECP) of stents, an electric mode based on direct current is traditionally used. The disadvantages of direct current ECP are excessive metal removal and the need to use electrolytes of complex compositions, often containing toxic components. As an alternative to the traditional ECP with the use of direct current, we have proposed a method of pulsed ECP using pulses of microsecond duration for polishing stents. The use of pulsed current allows one to achieve a significant increase in the efficiency of the SEC process, when, due to the localization of the anodic dissolution, the smoothing speed of the microroughness of the treated surface, referred to the total metal removal, increases significantly. The paper presents a comparative analysis of ECP modes using direct and pulse current to change the surface roughness, removal, radius of curvature of the edges, and corrosion resistance on the example of stents made of the 316LVM stainless steel. Based on the results of the studies, technological regimes of pulsed ECP were established that provide the highest quality polishing of the stent surface with a small metal removal with a slight rounding of the edges.
Publisher
Publishing House Belorusskaya Nauka
Reference31 articles.
1. Hill R.A., Dundar Y., Bakhai A., Dickson R., Walley T. Drug-eluting stents: an early systematic review to inform policy. European Heart Journal, 2004, vol. 25, no. 11, pp. 902–919. https://doi.org/10.1016/j.ehj.2004.03.023
2. Colombo A.,Iakovou I. Drug-eluting stents: the new gold standard for percutaneous coronary revascularization. European Heart Journal, 2004, vol. 25, no. 11, pp. 895–897. https://doi.org/10.1016/j.ehj.2004.04.004
3. Mani G., Feldman M. D., Patel D., Agrawal C. M. Coronary stents: a materials perspective. Biomaterials, 2007, vol. 28, no. 9, pp. 1689–1710. https://doi.org/10.1016/j.biomaterials.2006.11.042
4. Sojitra P., Engineer C., Kothwala D. M., Raval A. Electropolishing of 316LVM stainless steel cardiovascular stents: an investigation of materia removal, surface roughness and corrosion behavior. Trends in Biomaterials and Artificial Organs, 2010, vol. 23, no. 3, pp. 115–121.
5. Gellér Z. E. Albrecht K., Dobránszky J. Electropolishing of coronary. Materials Science Forum, 2008, vol. 589, pp. 367–372.
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献