Affiliation:
1. Northwest Institute of Nuclear Technology
Abstract
We proposed a Rayleigh–Brillouin scattering (RBS) spectrometer based on a virtually imaged phased array (VIPA) for fast measurements of high-gas temperature. We measured the RBS spectra of air in the temperature range of 374 to 1073 K with an acquisition time of 7 s. We used the Tenti S6 model to fit the spectra and retrieve the absolute temperature values. The root mean square errors of spectra fit residual were less than 3.05%, and the absolute error of the retrieved temperature was less than 39 K. This study demonstrated the ability of the RBS spectrometer to realize fast high-temperature measurement and its potential for combustion control applications.
Funder
National Natural Science Foundation of China
Natural Science Foundation of Jiangxi Province
Training Funding Project of High-Level and High-Skill Leading Talent of Jiangxi Province, China
Special Funding Project for National Key Laboratory of Intense Pulsed Radiation Simulation and Effect, China
Open Basic Research Program of Laboratory of Intense Dynamic Loading and Effect, China