Lacrimal and meibomian gland evaluation in dry eye disease: A mini-review

Author:

Singh Swati12,Donthineni Pragnya Rao3,Srivastav Saumya4,Jacobi Christina56,Basu Sayan3,Paulsen Friedrich2

Affiliation:

1. Ophthalmic Plastic Surgery Services, KAR Campus, Hyderabad, Telangana, India

2. The Cornea Institute, KAR Campus, Hyderabad, Telangana, India

3. Brien Holden Eye Research Centre, L V Prasad Eye Institute, Hyderabad, Telangana, India

4. Institute of Functional and Clinical Anatomy, Friedrich Alexander University Erlangen-Nuremberg, Erlangen, Germany

5. AUGEN and HAUT-Zentrum-Praxis Dr. Jacobi, Nuremberg, Germany

6. Friedrich Alexander University Erlangen-Nuremberg, Erlangen, Germany

Abstract

Lacrimal and meibomian glands contribute to the aqueous and lipid components of tear film, respectively. Their evaluation remains central to diagnosing and managing dry eye disease (DED). The review discusses the differences and reliability of various diagnostic tests and commercially available devices used for DED diagnosis. Slit-lamp-based techniques are direct palpebral lobe and tear flow assessment, Schirmer test, meibum quality and expressibility, and evaluation of tear meniscus height. Non-invasive tear meniscus height (TMH), tear break-up time (TBUT), lipid layer thickness (LLT), and meibography are machine-based diagnostic tests. The structure–function correlation of the tear-producing glands gives more comprehensive details than either information alone. Many devices are available in the market, which make DED diagnosis an easy feat, but the tests should be interpreted keeping in mind the intra-observer and inter-observer repeatability. Also, the tear film displays a huge variability as per the environmental conditions and impact of blinking. Hence, the examiner should be well versed with the techniques and repeat the test two to three times to obtain an average reading, which is more reliable. The recommended sequence of tests for diagnosing DED is a dry eye questionnaire, TMH, LLT, NIBUT (FBUT if non-invasive test is unavailable but should be performed after osmolarity), tear osmolarity, meibography, and ocular surface staining. Invasive tests such as Schirmer should be performed after the non-invasive tear film diagnostic testing.

Publisher

Medknow

Subject

Ophthalmology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3