Refractive outcomes of toric intra-ocular lens implantation in cases of high posterior corneal astigmatism

Author:

Jin Tianru1,Yu Lan1,Li Jingjing1,Zhou Yanwen1

Affiliation:

1. Department of Cataract Surgery, Shenyang Aier Eye Optometry Hospital, Shenyang, China

Abstract

Purpose: To evaluate whether the toric intra-ocular lens (IOL) power calculation based on total corneal astigmatism (TCA) in eyes with high posterior corneal astigmatism (PCA) could result in a systematic over-correction or under-correction after operation. Methods: The present study included a mono-centric retrospective study design. The data were collected from 62 consecutive eyes during uncomplicated cataract surgery by a single surgeon with a measured PCA of 0.50 diopters (D) or higher. Toric IOL calculations were made using TCA measurements. The eyes were grouped as either “with-the-rule” (WTR) or “against-the-rule” (ATR) on the basis of the steep anterior corneal meridian. The post-operative refractive astigmatic prediction error was analyzed 1 month post-operatively using the vector analysis by the Alpins method and double-angle plots method. Results: The correction indexes were 1.14 ± 0.29 in the ATR eyes and 1.25 ± 0.18 for the WTR eyes, indicating a tendency toward over-correction. The mean over-correction was 0.22 ± 0.52D in the ATR group and 0.65 ± 0.60D in the WTR group. The magnitude of error (ME) values were significantly different from the ideal value of zero in both groups (ATR: P = 0.03; WTR: P = 0.00). No significant difference in mean absolute error (MAE) in predicted residual astigmatism was found between ATR and WTR groups (0.61 ± 0.42 D versus 0.64 ± 0.39 D; P = 0.54). The ATR group yielded better results, with 48% <0.50D prediction error in the main analysis. Conclusions: The results suggested that in cases of high PCA, the toric IOL calculation, which was performed using TCA, may cause a potential over-correction in the ATR and WTR eyes. For ATR eyes, over-correction led to slight disruption of post-operative visual quality because of the “with-the-rule” residual astigmatism after operation. Therefore, we suggested using TCA for toric IOL calculation in ATR eyes.

Publisher

Medknow

Subject

Ophthalmology

Reference19 articles.

1. Prevalence of corneal astigmatism before cataract surgery;Ferrer-Blasco;J Cataract Refract Surg,2009

2. Toric intraocular lenses in the correction of astigmatism during cataract surgery:A systematic review and meta-analysis;Kessel;Ophthalmology,2016

3. Contribution of posterior corneal astigmatism to total corneal astigmatism;Koch;J Cataract Refract Surg,2012

4. Age-related changes in corneal astigmatism;Shao;J Refract Surg,2017

5. Comparison of corneal topography measurement with two different instruments;Wang;J Clin Ophthalmol,2013

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3