Comparison of marginal leakage and retentive strength of implant-supported milled zirconia and cobalt-chromium copings cemented with different temporary cements

Author:

Hendi Amirreza1,Falahchai Mehran1,Sigaroodi Saeid Hasanpour2,Asli Hamid Neshandar1

Affiliation:

1. Department of Prosthodontics, Dental Sciences Research Center, School of Dentistry, Guilan University of Medical Sciences, Rasht, Iran

2. School of Dentistry, Guilan University of Medical Sciences, Rasht, Iran

Abstract

ABSTRACT Background: Few studies assessed the effect of coping material (particularly milled metal copings) on the retentive strength of cements and reported contradictory results. Thus, this study aims to assess the marginal leakage and retentive strength of implant-supported milled zirconia and cobalt-chromium (Co-Cr) copings cemented with different temporary cements. Materials and Methods: In this in vitro study, Zirconia and Co-Cr copings were fabricated on 100 straight titanium abutments. Each group of copings was divided into five subgroups (n = 10) for the use of different cements: permanent zinc-phosphate (ZP) cement, temporary zinc oxide eugenol cement (temp bond [TB]), calcium hydroxide-based temporary cement (Dycal [DC]), polymer-based eugenol-free acrylic-urethane temporary cement (Dentotemp [DT]), and methacrylate-based temporary cement (Implantlink [IL]). The retentive strength and marginal leakage of restorations were assessed. Data were analyzed by one-way ANOVA, Tukey, and Fisher’s exact tests (α = 0.05). Results: In the Co-Cr group, the retentive strength values (in Newtons) were as follows: ZP (411.40 ± 5.19) >DC (248.80 ± 5.01) >IL (200.10 ± 5.06) >DT (157.90 ± 5.19) >TB (98.50 ± 6.88). This order was as follows in the zirconia group: ZP (388.70 ± 5.35) >DC (226.60 ± 5.08) >IL (179.00 ± 3.71) >DT (136.00 ± 4.88) >TB (78.60 ± 3.50). All pairwise comparisons were statistically significant (P < 0.001). The difference in marginal leakage was not significant among the groups (P = 0.480). Conclusion: The type of coping material and cement type significantly affected retentive strength, but not marginal leakage, of implant restorations. Milled Co-Cr copings showed higher retentive strength than zirconia copings, and ZP cement followed by DC yielded the highest retention.

Publisher

Medknow

Reference36 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3