Comparative evaluation of masticatory efficiency, clinical performance, and patient satisfaction of single implant-retained mandibular overdenture versus conventional complete denture: A prospective in vivo study

Author:

Mathew Jemin Elizabeth1,Kurian Nirmal1,Gandhi Nitasha1,Daniel Angleena Y.1,Roy Neethu1,Varghese Kevin George1

Affiliation:

1. Department of Prosthodontics and Crown and Bridge, Christian Dental College, Ludhiana, Punjab, India

Abstract

Aim: The aim of this within-subject prospective clinical study was to investigate the scope of single implant mandibular overdenture by assessing its masticatory efficiency, clinical performance, and patient satisfaction compared to conventional complete dentures. Settings and Design: Prospective In Vivo Study. Material and Methods: This prospective in vivo study was conducted in the Department of Prosthodontics and Crown and Bridge, Christian Dental College, Ludhiana. A total of 12 completely edentulous patients received a single implant in the mandibular anterior midline region. After the healing period, the conventional maxillary and mandibular dentures were fabricated. 15 days post insertion of the conventional dentures, patients were evaluated for masticatory efficiency, clinical performance including retention and stability, and patient satisfaction. To evaluate the masticatory efficiency blue raspberry and original pink “Hubba Bubba tape gum” were used as a test food. Colorimetric analysis was done to assess variance of hue. To assess clinical performance, retention, and stability of the mandibular denture was recorded using a digital force gauge and was tabulated as per CU-modified Kapur's criteria. OHIP-14 index was used to assess patient satisfaction. After evaluation of the parameters of conventional dentures, the denture was converted into an implant-retained mandibular denture by chairside conversion with locator attachments. 15 days post-implant loading, parameters of the implant retained mandibular overdenture were assessed again followed by statistical analysis. Statistical Analysis Used: The masticatory efficiency was assessed using a paired t-test. The patient satisfaction was sequentially assessed with Wilcoxon signed rank test and thereafter paired t-test was used to compare between conventional complete denture and overdenture. Clinical performance was assessed using the Wilcoxon signed rank test. Results: The masticatory efficiency of single implant mandibular overdenture was higher than that of conventional complete dentures. The clinical performance of the overdenture was higher than that of the conventional denture. Stability being a time-dependent parameter might need longer follow-ups for further conclusions. Patient satisfaction with single implant retained overdenture was significantly higher than conventional complete dentures. Conclusion: Single implant mandibular overdenture has improved masticatory efficiency, clinical performance, and patient satisfaction compared to conventional complete dentures.

Publisher

Medknow

Reference30 articles.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3