A comparative evaluation of internal and marginal fits of custom post and core fabricated using conventional and two digital techniques: An in vitro study

Author:

Sheth Vidhi Himanshu1,Gharat Nikita1,Bhatnagar Vishrut Mohan1,Gill Shruti1,Shah Naisargi P.1

Affiliation:

1. Department of Prosthodontics, Crown and Bridge, TPCT's Terna Dental College, Navi Mumbai, Maharashtra, India

Abstract

Aim: The purpose of this in vitro study was to comparatively evaluate the marginal and internal fits of cobalt–chromium metal custom post and core fabricated using a conventional technique with two digital techniques. Settings and Design: The study was designed in an in-vitro study setting. Materials and Methods: Five sets of custom post and core restorations were fabricated using the conventional (Group 1) and two semi digital methods (digital scanning of the resin pattern and computer aided additive manufacturing, and digital scanning of the silicone impression and subsequent computer aided designing [CAD] computer aided manufacturing fabrication) (Group 2 and 3). Marginal and internal fits of the posts were evaluated using a micro computed tomography scan at various points. Statistical Analysis Used: A one way ANOVA test of the scores was made to evaluate the effect of different methods of custom post and core fabrication on marginal and internal fits. Bonferroni adjusted post hoc tests were conducted for intergroup comparison. Results: Least marginal gap was reported in Group 3 (82.5 ± 14.36 μm) followed by Group 1 (110 ± 25.19 μm) and Group 2 (112.5 ± 26.75 μm). Least internal gap at cervical, middle and apical as well as overall values were observed in Group 3 (78 ± 9.25 μm, 72 ± 7.79 μm, 160 ± 15.81 μm, 103.3 ± 4.43 μm) followed by Group 1 (113.5 ± 25.35 μm, 132.5 ± 19.92 μm, 502 ± 74.63 μm, 249.3 ± 25.44 μm) and Group 2 (114.5 ± 21.68 μm, 133.5 ± 19.57 μm, 598 ± 87.86 μm, 282 ± 28.91 μm) respectively. The results of one-way ANOVA and Bonferroni adjusted post hoc tests for marginal gap did not show any statistically significant difference between the three groups (P > 0.05) but revealed statistically significant difference (P = 0.02) in internal gap values at the cervical, middle, and apical regions as well as overall internal gap region between the three groups. Conclusions: Better marginal and internal fits were observed in custom post and core fabricated by digital scanning of the silicone impression and subsequent CAD as compared to those fabricated by the other two groups.

Publisher

Medknow

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3