Comparative evaluation to study the effect of implant support on complete fixed dental prosthesis fabricated with peek framework when implants placed in all-on-4 and all-on-6 situation, by strain gauge analysis and finite element analysis – An in vitro study

Author:

Vinodh Shanmathi1,Jingade Ranganatha Rao K1,Ajjikuttira Ponnanna Appanna1,Kyathappa Prathima1,Nataraj Mamatha1,Chalana B. O.1

Affiliation:

1. Department of Prosthodontics and Implantology, Krishnadevaraya College of Dental Sciences and Hospital, Bengaluru, Karnataka, India

Abstract

Aim: To evaluate and compare the strain development and distribution of maxillary implant-supported complete fixed dental prosthesis (ISCFDP) with computer-aided design-computer-aided manufacturing milled PEEK BIO-HPP superstructure when placed using All-on-4 and All-on-6 situation using a strain gauge and finite element analysis (FEA). Setting and Design: This is an in vitro study to evaluate and compare the stress minimization and strain developed at implant in premolar and in two clinically simulated situation of All-on-4 and All-on -6 ISCFDP. Materials and Methods: The study involved converting a human skull into. stl format to create 3D-printed stereolithography models with a modulus of elasticity closer to bone. Implants were placed in two models (M1 nad M2) in incisor, premolar, and pterygoid regions. A fixed dental prosthesis framework was fabricated on both models, and strain gauge sensors were attached. Statistical Analysis Used: Descriptive and analytical statistics were done. The normality of data was analyzed by the Shapiro-Wilk test. Results: The results obtained were tabulated and it showed strain around the neck of ISCFDP under 100N configuration in strain gauge analysis. Stress was found more in the molar region when compared to the premolar region. This design showed that the largest stress around the neck of ISFDP under 100 N load was found more in the premolar region when compared to the molar region due to the reduction of stresses in the pterygoid region in FEA. Conclusion: In the present study, strain gauge analysis at 100 N for loading at the premolar and molar region shows the reduced strain on tilted implants in All-on-6 situation due to stress dissipation to the terminal pterygoid implant using strain gauge.

Publisher

Medknow

Subject

General Dentistry,Oral Surgery

Reference12 articles.

1. Rehabilitation of the atrophic posterior maxilla with pterygoid implants:A review;Candel;J Oral Implantol,2012

2. Pterygoid implant:Option for rehabilitation of the atrophic posterior maxilla;Nag;Int J Contemp Dent Med Rev,2019

3. Implants in the pterygoid region:A systematic review of the literature;Bidra;Int J Oral Maxillofac Surg,2011

4. The long-term efficacy of currently used dental implants:A review and proposed criteria of success;Albrektsson;Int J Oral Maxillofac Implants,1986

5. Effect of tilted and short distal implants on axial forces and bending moments in implants supporting fixed dental prostheses:An in vitro study;Ogawa;Int J Prosthodont,2010

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3