A comparative study to evaluate the cervical spine movements during laryngoscopy using Macintosh and Airtraq laryngoscopes

Author:

Kaur Kiranpreet1,Raja Rameez1,Kumar Prashant1,Singh Roop2,Vashishth Sumedha1,Singh Harshil D.3,Bhardwaj Mamta1,Singhal Suresh K.1

Affiliation:

1. Department of Anaesthesiology and Critical Care, Pt. B.D. Sharma PGIMS, Rohtak, Haryana, India

2. Department of Orthopaedics, Pt. B.D. Sharma PGIMS, Rohtak, Haryana, India

3. Department of Computer Science, IIIT UNA, Himachal Pradesh, India

Abstract

Abstract Background and Aim: Intubation with Macintosh requires flexing the lower cervical spine and extending the atlanto-occipital joint to create a “line of sight.” Primary aim of study was to compare the extent of cervical spine movement during laryngoscopy using conventional Macintosh laryngoscope and Airtraq. Material and Methods: A total of 25 patients of either sex between the age group of 18 and 60 years, having American Society of Anesthesiologists (ASA) physical status of Grade-I and Grade-II, scheduled for elective surgery under image control requiring general anesthesia and intubation were enrolled. A baseline image of the lateral cervical spine including the first four cervical vertebrae was taken by an image intensifier. After administration of general anesthesia, laryngoscopy was first performed using a Macintosh laryngoscope and a second X-ray image of the lateral cervical spine was taken. The second laryngoscopy using a Airtraq laryngoscope was done and the third image of the lateral cervical spine was taken. Angles between occiput and C1; C1 and C2; C2 and C3; C3 and C4; and occiput and C4 were calculated. Atlanto-occipital distance (AOD) was calculated as the distance between occiput and C1. Results: Macintosh showed greater cervical movement as compared with Airtraq but a significant difference in the movement was observed at C2–C3 and C0–C4. Baseline mean AOD was 2.21 ± 1.25 mm, after Macintosh and Airtraq laryngoscopy was found to be 1.13 ± 0.60 and 1.6 ± 0.78 mm, respectively, and was found to be significant (P < 0.05). Conclusion: We conclude that Airtraq allows intubation with less movement of the upper cervical spine makes Airtraq preferred equipment for intubation in patients with a potential cervical spine injury.

Publisher

Medknow

Subject

Anesthesiology and Pain Medicine,Pharmacology (medical),General Pharmacology, Toxicology and Pharmaceutics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3