1. From the Department of Plastic Surgery, Wythenshawe Hospital, Manchester, UK
Abstract
The use of dynamic traction splintage is established in the treatment of complex intra-articular phalangeal fractures. Several different systems have been used and we report our experience with one of these, the Pins and Rubber Traction System. A cohort of 14 patients with complex intra-articular fractures at the base of the middle phalanges of the fingers were treated and assessed prospectively over a 2.5-year period (mean, 20 months; range, 7–28 months). The mean active range of motion regained, at the proximal interphalangeal joint, was 74° (range, 0–100°). The mean total active motion of the injured digit was 196° (range, 40–275°). Refinements in the regime are suggested as a result of this investigation.