Partial Least Squares Based Decomposition of Five Spectrally Overlapping Factors

Author:

Pomerleau-Dalcourt Natalie1,Weersink Robert1,Lilge Lothar1

Affiliation:

1. Department of Medical Biophysics, University of Toronto, Toronto, ON, Canada M5G 2M9 (N.P.-D., L.L.); and Ontario Cancer Institute, Princess Margaret Hospital, Toronto, ON, Canada M5G 2M9 (R.W., L.L.)

Abstract

The development of a multi-sensory fiber-optic based fluence rate probe (MSP) for light monitoring and dosimetry during photodynamic therapy (PDT) created the need for a robust multivariate signal analysis algorithm capable of quantifying the intensity of five component spectra, representing the sensors, which display a large degree of spectral overlap. Partial least squares (PLS) analysis, as an option for such an analysis algorithm, was evaluated through simulations in the presence of three types of noise, which experimentally may limit the accuracy of PLS quantification of component spectra contributions. Random, or white noise, background was varied over a range of 0–15% relative intensity. A non-random (Gaussian) background vector was simulated, as an experimentally relevant spectral interferent, over a range of 0–7% relative intensity. Spectral variation was modeled by a spectral shift of ±1–5 nm. Procedures for selecting preferred combinations of fluorophores, with minimum possible spectral overlap, were developed. To illustrate the importance of this selection process, PLS performance results were compared for two possible combinations of five fluorophores, as well as for the combination of three fluorophores currently in experimental use with MSPs. Experimentally anticipated worst-case quantifications were identified for all three types of simulated noise (5% random background, 0.5% Gaussian background, and ±2 nm spectral shift). The effects of single and combined types of noise were evaluated by independently varying each type of simulated noise over the experimentally relevant range. The mean percentage error in determining the fluorophore contributions and hence quantification of the fluence rate were compared with the required performance standard of better than 10% error for optical power meters in medical use. The PLS algorithm provided an accuracy of 7 ± 2% for five fluorophores and 3.3 ± 0.8% for three fluorophores, indicating that PLS is an appropriate choice for this application.

Publisher

SAGE Publications

Subject

Spectroscopy,Instrumentation

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3