Reliability and validity of measuring shoulder joint flexion using digital and standard goniometric methods

Author:

Jovanović StevanORCID,Nedović NenadORCID,Vujičić DaniloORCID,Teovanović PredragORCID

Abstract

Based on the literature review and clinical experiences, it can be concluded that measuring the amplitude of movement is one of the fundamental kinesiometric methods used in assessing joint functionality. The aim of this study was to examine the reliability and validity of measuring the shoulder joint's range of motion using the digital system KEMTAI compared to a goniometer with arms. This non-experimental observation was conducted on 40 participants whose flexion range in the shoulder joint was measured using both the goniometer with arms and the KEMTAI software system, which utilizes the examiner's mobile phone camera. The results indicated that the lowest mean value was obtained during the first measurement session (M1 = 154.68), while the highest was during the third session (M2 = 156.53). When using the KEMTAI software, the variability of mean values for the total tested population was significantly higher than when using the goniometer with arms. The results suggest that the KEMTAI software/system is reliable when comparing the average results of three measurements. Based on these findings, it is concluded that three experienced measurers demonstrated high reliability in measuring the shoulder joint's flexion range using the goniometer with arms. Despite the identified differences between the measurement results obtained using these two methods, it is considered that the KEMTAI software/system is applicable in practical work.

Publisher

Centre for Evaluation in Education and Science (CEON/CEES)

Reference12 articles.

1. Achachagua, A.J. Y., Saucedo, P. S., Lalupú, J. C., Vargas, D. E., Anzualdo, VI. T. (2021). Confiabilidad testretest de goniometría estándar y G-pro smartphone en el movimiento flexo-extensión del hombro [Test-retest reliability of standard goniometry and the G-pro smartphone in shoulder flexion-extension]. Rehabilitacion (Madr) 55:183-189. doi:10.1016/j.rh.2020.11.003;

2. Bovens, A.M., van Baak, M.A., Vrencken, J.G., Wijnen, J.A., Verstappen, F.T. (1990). Variability and reliability of joint measurements. The American Journal of Sports Medicine 18:58-63. doi:10.1177/036354659001800110;

3. Correll, S., Field, J., Hutchinson, H., Mickevicius, G., Fitzsimmons, A., Smoot, B. (2018). Reliability and validity of the halo digital goniometer for shoulder range of motion in healthy subjects. International Journal of Sports Physical Therapy 13:707-714;

4. Fraeulin, L., Holzgreve, F., Brinkbäumer, M., Dziuba, A., Friebe, D., Klemz, S., Schmitt, M., A, L. T., Tenberg, S., Maurer-Grubinger, C., Ohlendorf, D. (2020). Intra-and inter-rater reliability of a joint range of motion tests using tape measure, digital inclinometer, and inertial motion capturing. PLoS One 15. doi:10.1371/journal.pone.0243646;

5. Hawi, N., Liodakis, E., Musolli, D., Suero, E.M., Stuebig, T., Claassen, L., Kleiner, C., Krettek, C., Ahlers, V., Citak, M. (2014). Range of motion assessment of the shoulder and elbow joints using a motion sensing input device: a pilot study. Technology and health care: official journal of the European Society for Engineering and Medicine 22:289-95. doi:10.3233/THC-140831;

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3