Pulse oximetry methods: opportunities and limitations

Author:

Garanin A. A.1ORCID,Dyachkov V. A.1ORCID,Rubanenko A. O.1ORCID,Reprintseva O. A.1ORCID,Duplyakov D. V.1ORCID

Affiliation:

1. Samara State Medical University

Abstract

The aim of this review was to evaluate the current literature on various methods of pulse oximetry, their advantages and disadvantages. Modern pulse oximetry methods generally correlate well with invasive saturation monitoring, which makes it possible to be widely used in clinical practice. At the same time, in order to improve the accuracy of saturation measurements, existing limitations of various pulse oximetry methods should be taken into account. The emergence and introduction into clinical practice of reflectance pulse oximetry can largely compensate for the limitations of traditional transmission pulse oximetry regarding peripheral hypoperfusion, low response time, and features of patient's nails. In the event of special situations when pulse oximetry may not be accurate enough (carbon monoxide poisoning, methemoglobinemia, severe anemia, severe tricuspid insufficiency, etc.), a thorough clinical assessment of the patient is recommen ded, as well as invasive saturation monitoring.

Publisher

Silicea - Poligraf, LLC

Subject

Cardiology and Cardiovascular Medicine

Reference34 articles.

1. Bajmakanova GE. Interpretation of arterial blood gas indicators. Pulmonology and allergology. 2013;2:42-5. (In Russ.)

2. Egorova MO. Gas-electrolyte composition of blood and informative parameters of its evaluation. Directory of the head of the CDL. 2017;9: 41-54. (In Russ.)

3. Perkins GD, McAuley DF, Giles S, et al. Do changes in pulse oximeter oxygen saturation predict equivalent changes in arterial oxygen saturation? Crit Care. 2003;7(4):R67. doi:10.1186/cc2339.

4. Polidanov MA. Pulse oximetry: the essence of technology and modern technical means. Modern Science. 2019;12(4):137-40. (In Russ.)

5. Sigal ZM, Bryndin VV, Meshchanov SYu, et al. Possibilities of pulse oximetry application in clinical practice (literature review). Health, demography, ecology of the Finno-Ugric peoples. 2017;(4):81-5. (In Russ.)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3