X-ray streak camera tube with two photocathodes

Author:

Li Jin,Yang Pin,Yang Zhi-Wen,Zhang Xing,Liu Shen-Ye,Dong Jian-Jun,Yang Zheng-Hua,Ren Kuan,Li Ying-Jie,Zhang Lu,Hu Xin,

Abstract

<sec>The time-resolved X-ray spectroscopy measurement system based on X-ray streak camera technology is indispensable diagnostic equipment in the study of laser inertial fusion research and high-energy-density physics. However, limited by the effective photocathode length of the X-ray streak tube, the time-resolved spectral measurement system usually used has the shortcomings of narrow spectrum range and poor spectral resolution.</sec><sec>In order to overcome the shortcomings, a novel dual-channel streak tube is developed, which consists of a photocathode, a prefocusing electrode group in temporal direction, an electric quadrupole lens electrode group, a main focusing electrode group in temporal direction, a deflector plate, and a phosphor screen. The photocathode has two slits. When X-rays are incident, two electron beams can be emitted simultaneously. The electric quadrupole lens electrode group is composed of 8 arc electrodes. Two electric quadrupole lenses are formed by the 8 arc electrodes in the spatial direction. Two electron beams emitted from the cathode of the streak tube are first accelerated and prefocused by the prefocusing electrode group in the time direction, and then compressed by the main focusing electrode group in the time direction. In the spatial direction, two electron beams are focused by the two electric quadrupole lenses independently. This novel streak tube structure can focus two electron beams at the same time, thereby increasing the effective photocathode length and maintaining the compact structure of streak tube without increasing the aberration.</sec><sec>The cathode voltage of the designed streak tube is –12 kV, the distance from cathode to grid is 5 mm, and the cathode-grid field strength is 2.4 kV/mm. The cathode is divided into two sections, the spacing between sections is about 13 mm, the length of each section is more than 20 mm, the magnification of the image converter tube is about 1.56 times, the distance between the cathode and the phosphor screen is 300 mm, and the longest size along the cathode direction is 90 mm. The test results of the performance of the streak tube show that the actual effective cathode length of the developed tube reaches 44 mm, the spatial resolution is better than 15 lp/mm, and the deflection sensitivity is better than 40 mm/kV. The effective cathode and spatial resolution of the tube can be increased to 50 mm and 25 lp/mm by further optimizing the structure of the tube and removing the image intensifier with a high sensitivity image recording system, respectively.</sec>

Publisher

Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences

Subject

General Physics and Astronomy

全球学者库

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"全球学者库"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前全球学者库共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2023 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3