Swimming With the COSMED AquaTrainer and K5 Wearable Metabolic System in Breath-by-Breath Mode: Accuracy, Precision, and Repeatability

Author:

Zacca Rodrigo1234ORCID,Castro Flávio Antônio de Souza5ORCID,Monteiro Ana Sofia Mottini1ORCID,Pyne David B.6ORCID,Vilas-Boas João Paulo12ORCID,Fernandes Ricardo Jorge Pinto12ORCID

Affiliation:

1. Faculty of Sport (FADEUP), Center of Research, Education, Innovation and Intervention in Sport (CIFI2D), University of Porto, Porto, Portugal

2. Porto Biomechanics Laboratory (LABIOMEP-UP), University of Porto, Porto, Portugal

3. Faculty of Sports (FADEUP), Research Center in Physical Activity, Health and Leisure (CIAFEL), University of Porto, Porto, Portugal

4. Laboratory for Integrative and Translational Research in Population Health (ITR), Porto, Portugal

5. Aquatic Sports Research Group (GPEA), School of Physical Education, Physiotherapy and Dance, Universidade Federal do Rio Grande do Sul, Porto Alegre, Brazil

6. University of Canberra Research Institute for Sport and Exercise (UCRISE), Canberra, Australia

Abstract

Purpose: To compare ventilatory and cardiorespiratory responses between the COSMED AquaTrainer coupled with the K4b2 and K5 wearable metabolic systems in breath-by-breath mode over a wide range of swimming speeds. Methods: Seventeen well-trained master swimmers performed 2 front-crawl 7 × 200-m incremental intermittent protocols (increments of 0.05 m·s−1 and 30-s rest intervals, with a visual pacer) with AquaTrainer coupled with either K4b2 or K5. Results: Post hoc tests showed that swimming speed was similar (mean diff.: −0.01 to 0.01 m·s−1; P = .73–.97), repeatable (intraclass correlation coefficient: .88–.99; P < .001), highly accurate, and precise (agreement; bias: −0.01 to 0.01 m·s−1; limits: −0.1 to 0.1 m·s−1) between all conditions. Ventilatory and cardiorespiratory responses were highly comparable between all conditions, despite a “small” effect size for fraction of expired carbon dioxide at the sixth 200-m step (0.5%; ; P = .04) and carbon dioxide production at the fifth, sixth, and seventh 200-m steps (0.3–0.5 L·min−1; –.17; P = .01–.05). We also observed high accuracy, which was greater for tidal volume (0.0–0.1 L), minute ventilation (−3.7 to 5.1 L·min−1), respiratory frequency (bias: −2.1 to 1.9 breaths·min−1), and oxygen uptake (0.0–0.2 L·min−1). Bland–Altman plots showed that the distribution inside the limits of agreement and their respective 95% CIs were consistent for all ventilatory and cardiorespiratory data. The repeatability (intraclass correlation coefficient) of tidal volume (.93–.97), minute ventilation (.82–.97), respiratory frequency (.68–.96), fraction of expired carbon dioxide (.85–.95), carbon dioxide production (.77–.95), fraction of expired oxygen (.78–.92), and oxygen uptake (.94–.98) data ranged from moderate to excellent (P < .001–.05). Conclusions: Swimming with the AquaTrainer coupled with K5 (breath-by-breath mode) yields accurate, precise, and repeatable ventilatory and cardiorespiratory responses when compared with K4b2 (previous gold standard). Swimming support staff, exercise and health professionals, and researchers can now relate differences between physiological capacities measured with the AquaTrainer while coupled with either of these 2 devices.

Publisher

Human Kinetics

Subject

Orthopedics and Sports Medicine,Physical Therapy, Sports Therapy and Rehabilitation

Reference41 articles.

1. Studien über die Physiologie des Schwimmens;Liljestrand G,1920

2. The oxygen consumption during running—Proceedings of the physiological society;Hill AV,1922

3. The energy cost of human locomotion on land and in water;di Prampero PE,1986

4. The energy cost of swimming and its determinants;Zamparo P,2020

5. ARTP statement on cardiopulmonary exercise testing 2021;Pritchard A,2021

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3