A Comparison of Physiological Response to Incremental Testing on Stationary and Dynamic Rowing Ergometers

Author:

Boland Marie,Crotty Nora May,Mahony Nick,Donne Bernard,Fleming Neil

Abstract

Purpose: The purpose of the current study was to compare responses to graded exercise testing (GXT) on 2 popular commercial rowing ergometers. Methods: A cohort of 23 subelite male rowers (age 20 [2] y, height 1.88 [0.06] m, body mass 82.0 [8.8] kg) performed a GXT on both stationary (Concept2 [C2]) and dynamic (RowPerfect3 [RP3]) rowing ergometers. Physiological responses including oxygen consumption (VO2), heart rate (HR), blood lactate concentration (BLa), stroke rate (SR), and minute ventilation (VE) were recorded. BLa data were plotted graphically and anaerobic threshold was identified using the Dmax method. Workload, HR, and VO2 at Dmax were interpolated. Physiological responses at maximal exercise and at Dmax were compared, along with response across a discrete range of submaximal workloads. Results: At maximal exercise, no significant differences in HR, VO2, or BLa were observed (P > .05); however, VEpeak was significantly higher during RP3 tests (T = 2.943, P < .05). No significant differences in HR, VO2, or BLa at Dmax were observed (P > .05). When comparing across submaximal workloads, HR was significantly higher with the RP3 at 2 distinct workloads (210 and 240 W; P < .05), while SR was higher during RP3 testing at all workloads (F = 56.7, P < .05). When SR was fixed as a covariate, the effect of ergometer on HR response was not significant. A significant workload by ergometer interaction effect was observed for SR with higher data recorded on the RP3 (F = 3.48, P < .01). Levels of agreement for GXT-derived measures of anaerobic threshold (Dmax) were deemed unacceptable. Conclusions: These results indicate that while some differences in HR and VE response were observed between ergometers, these differences were a result of SR alterations between ergometer type. While no differences in response at Dmax were observed, the poor levels of agreement between ergometers suggests that prescription of GXT-derived threshold for training should ideally be specific to the rowing ergometer upon which the test was performed.

Publisher

Human Kinetics

Subject

Orthopedics and Sports Medicine,Physical Therapy, Sports Therapy and Rehabilitation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3