Comparison of Tonovet® and Tonovet plus® tonometers for measuring intraocular pressure in dogs, cats, horses, cattle, and sheep

Author:

Kovalcuka Liga1ORCID,Mālniece Aija1ORCID,Vanaga Jana1

Affiliation:

1. Clinical Institute, Faculty of Veterinary Medicine, Latvia University of Life Sciences and Technologies, Jelgava, LV-3004, Latvia.

Abstract

Background and Aim: Reference ranges for intraocular pressure (IOP) in healthy animals are device-specific; therefore, it is strongly recommended to use appropriate reference values according to the device. Therefore, our aim was to compare IOP readings made by TonoVet® and TonoVet Plus® in healthy dogs, cats, sheep, cattle, and horses. We compared IOP values measured by TonoVet® and TonoVet Plus® tonometers in clinically normal eyes of dogs, cats, horses, cattle, and sheep. Materials and Methods: Five groups comprising 20 animals each of dogs (various breeds, 9 months–10 years old, 14 females, 6 males), cats (various breeds, 6 months–12 years old, 8 females, 12 males), horses (various breeds, 5–12 years old, 12 females, 8 males), cattle (Holstein, 1–7 lactation, female), and sheep (Latvian Darkhead ewes, 1–8 years old) were included in the study. Both eyes of all animals were subjected to ophthalmic examination, including evaluation of IOP by rebound tonometry using TonoVet® and TonoVet Plus® devices. Normality was determined using the Shapiro–Wilk test. The independent t-test was used to determine differences between IOP values in the right and left eyes and between both tonometers. This study was approved by the Ethical Commission of the Latvia University of Life Sciences and Technologies (Nr. LLU_Dzaep_2022-2-4). Results: No differences in IOP between the right and left eyes were found in all cases (p > 0.05). The mean IOP ± standard deviation values in both eyes for TonoVet® and TonoVet Plus® tonometers were as follows: for dogs, 15.25 ± 2.73 mmHg and 19.65 ± 3.46 mmHg; and in cats, 18.88 ± 3.98 mmHg and 18.78 ± 4.26 mmHg, respectively. In horses, mean IOP was 22.15 ± 3.74 mmHg and 24.28 ± 3.00 mmHg; in cattle, 24.73 ± 2.89 mmHg and 23.28 ± 2.97 mmHg; and in sheep, 18.05 ± 3.54 mmHg and 22.49 ± 4.66 mmHg, respectively. Significant differences in IOP values were observed between the tonometers in sheep, dog, and horse groups (mean difference –4.40, –4.48, and 2.13, respectively). Conclusion: This study showed significantly higher IOP values measured by the TonoVet Plus® tonometer in dogs and sheep. Keywords: cats, cattle, dogs, horses, sheep, TonoVet plus, TonoVet.

Funder

Lavijas Lauksaimniecības Universitāte

Publisher

Veterinary World

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3