Awake Fiberoptic or Awake Video Laryngoscopic Tracheal Intubation in Patients with Anticipated Difficult Airway Management

Author:

Rosenstock Charlotte V.1,Thøgersen Bente2,Afshari Arash3,Christensen Anne-Lise4,Eriksen Claus4,Gätke Mona R.5

Affiliation:

1. Consultant, Associate Professor, Department of Anesthesiology, Copenhagen University Hospital, Hillerød, Denmark.

2. Consultant, Department of Anesthesiology, Copenhagen University Hospital, Herlev, Denmark.

3. Consultant, Copenhagen University Hospital, Rigshospitalet, Department of Anesthesia, Juliane Marie Centre, Denmark.

4. Consultant, Department of Anesthesiology, Copenhagen University Hospital, Hillerød, Denmark.

5. Consultant, Associate Professor, Department of Anesthesiology, Copenhagen University Hospital, Herlev, Denmark.

Abstract

Background Awake flexible fiberoptic intubation (FFI) is the gold standard for management of anticipated difficult tracheal intubation. The purpose of this study was to compare awake FFI to awake McGrath® video laryngoscope, (MVL), (Aircraft Medical, Edinburgh, Scotland, United Kingdom) intubation in patients with an anticipated difficult intubation. The authors examined the hypothesis that MVL intubation would be faster than FFI. Methods Ninety-three adult patients with anticipated difficult intubation were randomly allocated to awake FFI or awake MVL, patients were given glycopyrrolate, nasal oxygen, topical lidocaine orally, and a transtracheal injection of 100 mg lidocaine. Remifentanil infusion was administered intravenously to a Ramsay sedation score of 2-4. Time to tracheal intubation was recorded by independent assessors. The authors also recorded intubation success on the first attempt, investigators' evaluation of ease of the technique, and patients reported intubation-discomfort evaluated on a visual analog scale. Results Eighty-four patients were eligible for analysis. Time to tracheal intubation was median [interquartile range, IQR] 80 s [IQR 58-117] with FFI and 62 s [IQR 55-109] with MVL (P = 0.17). Intubation success on the first attempt was 79% versus 71% for FFI and MVL, respectively. The median visual analog scale score for ease of intubation was 2 (IQR 1-4) versus 1 (IQR 1-6) for FFI and MVL, respectively. The median visual analog scale score for patients' assessment of discomfort for both techniques was 2, FFI (IQR 0-3), MVL (IQR 0-4). Conclusions The authors found no difference in time to tracheal intubation between awake FFI and awake MVL intubation performed by experienced anesthesiologists in patients with anticipated difficult airway.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference18 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3