Preoperative Imaging in Cochlear Implants

Author:

Lee Andrew Y.1,Lee Diana Y.2,Saunders James E.

Affiliation:

1. Geisel School of Medicine at Dartmouth, Hanover, New Hampshire

2. New York University Langone Health, Towson, Maryland

Abstract

Objective To determine the utility of computed tomography (CT) and magnetic resonance imaging (MRI) in cochlear implant candidates. Study Design Retrospective case review. Setting Tertiary referral hospital. Patients A total of 207 cochlear implanted patients with CT and/or MRI Intervention(s) N/A. Main Outcome Measure(s) Age versus abnormal radiologic findings, imaging abnormality versus postoperative outcomes, postoperative outcomes versus electrode design, Cambridge Cochlear Implant Protocol (CCIP) status for imaging abnormalities, sensitivity and specificity of CT and MRI for round-window/cochlear occlusion, and MRI for incomplete partitions. Results A total of 207 patients with CT, MRI, or both were reviewed retrospectively. Less than half (15.5%) of CT scans had findings that might affect surgical intervention compared with 5.9% of MRI. No significant difference was found between children and adults for relevant imaging abnormalities (grade 4 or higher) with either CT (p = 0.931) or MRI (p = 0.606). CCIP status correlated with cochlear abnormalities (p = 0.040); however, only 46.2% of radiographic abnormalities on CT would be identified by these criteria. For detecting cochlear occlusion requiring surgical intervention, the sensitivity and specificity for CT were 40% (4 of 10; 95% confidence interval [CI], 12.16–73.76) and 95.73% (95% CI, 91.40–98.27), respectively. For MRI, the sensitivity and specificity were 33.33% (1 of 3; 95% CI, 0.84–90.57) and 96.97% (63 of 65; 95% CI, 89.32–99.63), respectively. There was no difference for postoperative AzBio scores for higher-grade imaging abnormalities (p = 0.6012) or for electrode designs (p = 0.3699). Conclusions Significant radiographic abnormalities were relatively uncommon in cochlear implant patients on either CT or MRI at our single-center institution. If present, abnormal imaging findings rarely translated to management changes. CCIP status does not reliably predict which patients are likely to have abnormalities. Both MRI and CT have low sensitivity for round-window or cochlear occlusion, but detection likely leads to changes in surgical management.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3