Abstract

Hypotheses In newly implanted cochlear implant (CI) users, electrically evoked compound action (eCAPs) and electrocochleography (ECochGs) will remain stable over time. Electrode impedances will increase immediately postimplantation due to the initial inflammatory response, before decreasing after CI switch-on and stabilizing thereafter. Background The study of cochlear health (CH) has several applications, including explaining variation in CI outcomes, informing CI programming strategies, and evaluating the safety and efficacy of novel biological treatments for hearing loss. Very early postoperative CH patterns have not previously been intensively explored through longitudinal daily testing. Thanks to technological advances, electrode impedances, eCAPs, and ECochGs can be independently performed by CI users at home to monitor CH over time. Methods A group of newly implanted CI users performed daily impedances, eCAPs, and ECochGs for 3 months at home, starting from the first day postsurgery (N = 7) using the Active Insertion Monitoring system by Advanced Bionics. Results Measurement validity of 93.5, 93.0, and 81.6% for impedances, eCAPs, and ECochGs, respectively, revealed high participant compliance. Impedances increased postsurgery before dropping and stabilizing after switch-on. eCAPs showed good stability, though statistical analyses revealed a very small but significant increase in thresholds over time. Most ECochG thresholds did not reach the liberal signal-to-noise criterion of 2:1, with low threshold stability over time. Conclusion Newly implanted CI recipients can confidently and successfully perform CH recordings at home, highlighting the valuable role of patients in longitudinal data collection. Electrode impedances and eCAPs are promising objective measurements for evaluating CH in newly implanted CI users.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3