Design and development of a noninvasive ocular pressure estimator

Author:

Karthikeyan Siddharth K.1,Sundaram Swaminathan M.,Ve Ramesh S.1,Souza Donson D.2,Biswas Sayantan,Shetty Mayur U.2

Affiliation:

1. Department of Optometry, Manipal College of Health Professions (MCHP), Manipal Academy of Higher Education (MAHE), Manipal, Karnataka, India

2. Blackfrog Technologies Pvt Ltd, Manipal, Karnataka, India

Abstract

SIGNIFICANCE A snapshot intraocular pressure (IOP) is ineffective in identifying the IOP peak and fluctuation, especially during sleep. Because IOP variability plays a significant role in the progression of glaucoma, monitoring the IOP, especially during sleep, is essential to capture the dynamic nature of IOP. PURPOSE We aimed to design an ocular pressure estimator (OPE) that can reliably and accurately measure the IOP noninvasively over closed-eyelid condition. METHODS Ocular pressure estimator works on the principle that the external pressure applied by raising the IOP of the eyeball is transmitted through a compressible septum to the pressure sensor, thus recording the IOP. A fluid-filled pouch with a pressure sensor was placed over a rubber glove mimicking the eyelid (septum), covering the cornea of enucleated goat eyeballs. A pressure-controlled setup was connected to a goat cadaver eye, which was validated by a rebound tonometer. Cannulation of eyeballs through the lower limbus had the least difference from the control setup values documented using rebound tonometer, compared with cannulation through the optic nerve. Intraocular pressures ranging from 3 to 30 mmHg was induced, and the outputs recorded using OPE were amplified and recorded for 10 minutes (n = 10 eyes). We stratified the randomization of the number of times and the induced pressures. RESULTS The measurements recorded were found to be linear when measured against an IOP range of 3 to 30 mmHg. The device has excellent reliability (intraclass correlation coefficient, 0.998). The repeatability coefficient and coefficient of variations were 4.24 (3.60 to 4.87) and 8.61% (7.33 to 9.90), respectively. The overall mean difference ± SD between induced IOP and the OPE was 0.22 ± 3.50 (95% confidence interval, −0.35 to 0.79) mmHg across all IOP ranges. CONCLUSIONS Ocular pressure estimator offers a promising approach for reliably and accurately measuring IOP and its fluctuation noninvasively under a condition mimicking a closed eye.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Reference38 articles.

1. The Pathophysiology and Treatment of Glaucoma: A Review;JAMA,2014

2. Global Data on Visual Impairment in the Year 2002;Bull World Health Organ,2004

3. Intraocular Pressure Fluctuation and Glaucoma Progression: What Do We Know?;Br J Ophthalmol,2014

4. Glaucoma in India: Estimated Burden of Disease;J Glaucoma,2010

5. Noninvasive Intraocular Pressure Monitoring: Current insights;Clin Ophthalmol,2015

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3