Twenty versus 40 back-and-forth needle movements for endoscopic ultrasound-guided fine-needle biopsy of solid pancreatic masses: a prospective, crossover, randomized study

Author:

Hu Xinyi12,Yu Fang13,Cao Tingting12,Chen Xiaojia12,Nie Haihang12,Zhang Zhang12,Wang Fan12,Wang Hongling12,Fang Jun12,Zhao Qiu12

Affiliation:

1. Department of Gastroenterology, Zhongnan Hospital of Wuhan University

2. Clinical Center and Key Lab of Intestinal and Colorectal Diseases of Hubei Province

3. Department of Pathology, Zhongnan Hospital of Wuhan University, Wuhan, China

Abstract

Background and aims In endoscopic ultrasound (EUS)-fine-needle biopsy (FNB) of solid pancreatic mass lesions, the number of times the needle moves back and forth within the lesion might affect the collection of the sample and the subsequent diagnostic accuracy. Thus, this study was designed to compare the diagnostic adequacy between different numbers of back-and-forth movements in EUS-FNB. Methods Fifty-five patients with solid pancreatic masses underwent EUS-FNB sampling with the needle (22-gauge) moved 20 times (MTT) and 40 times (MFT) randomly and sequentially for a total of four alternating passes. We compared the acquisition rate of appropriate and adequate specimens for histologic assessment and diagnostic accuracy. Results Finally, 55 patients (35 men and 20 women) were included in the study. We found that 56.4% (31/55) and 60% (33/55) of the specimens obtained using MTT and MFT, respectively, could be adequately diagnosed histologically (P = 0.815, McNemar test). The diagnostic accuracy of MTT and MFT was 72.7% (40/55) and 80% (44/55), respectively (P = 0.289, McNemar test). The overall diagnostic accuracy was 89.1%. Conclusion There was no significant statistical difference between the histopathological diagnostic samples obtained in MTT and those obtained in MFT. Therefore, a large number of back-and-forth movements of the needle should be avoided during EUS-FNB, which can help reduce the operation time and may reduce the risk of intraoperative and postoperative complications (Clinical trial registration number: ChiCTR2000031106).

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Gastroenterology,Hepatology

全球学者库

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"全球学者库"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前全球学者库共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2023 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3