ARTERIAL DIAMETER VARIATIONS AS A NEW INDEX FOR STROKE VOLUME ASSESSMENT: AN EXPERIMENTAL STUDY ON A CONTROLLED HEMORRHAGIC SHOCK MODEL IN PIGLETS

Author:

Ajavon Florian,Coisy Fabien,Grau-Mercier Laura,Fontaine Jules1,Perez Martin Antonia,Claret Pierre-Géraud1,Bobbia Xavier

Affiliation:

1. Department of Anesthesiology, Emergency and Critical Care Medicine, Intensive Care Unit, Nîmes University Hospital, Montpellier University, Nîmes, France

Abstract

ABSTRACT Background: The assessment of cardiac output (CO) is a major challenge during shock. The criterion standard for CO evaluation is transpulmonary thermodilution, which is an invasive technique. Speckle tracking is an automatized method of analyzing tissue motion using echography. This tool can be used to monitor pulsed arterial diameter variations with low interobserver variability. An experimental model of controlled hemorrhagic shock allows for multiple CO variations. The main aim of this study is to show the correlation between the femoral arterial diameter variations (fADVs) and the stroke volume (SV) measured by thermodilution during hemorrhagic shock management and the resuscitation of anesthetized piglets. The secondary objective is to explore the respective correlations between SV and subaortic time-velocity index, abdominal aorta ADV, carotid ADV, and subclavian ADV. Methods: Piglets were bled until mean arterial pressure reached 40 mm Hg. Controlled hemorrhage was maintained for 30 minutes before randomizing the piglets to three resuscitation groups—the fluid-filling group (reanimated with saline solution only), NEph group (norepinephrine + saline solution), and Eph group (epinephrin + saline solution). Speckle tracking, echocardiographic, and hemodynamic measures were performed at different stages of the protocol. Results: Thirteen piglets were recruited and included for statistical analysis. Of all the piglets, 164 fADV measures were attempted and 160 were successful (98%). The correlation coefficient between fADV and SV was 0.71 (95% confidence interval [CI], 0.62 to 0.78; P < 0.01). The correlation coefficient between SV and abdominal aorta ADV, subclavian ADV, and carotid ADV was 0.30 (95% CI, 0.13 to 0.46; P < 0.01), 0.56 (95% CI, 0.45 to 0.66, P < 0.01), and 0.15 (95% CI, −0.01 to 0.30, P = 0.06), respectively. Conclusions: In this hemorrhagic shock model using piglets, fADV was strongly correlated with SV.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Critical Care and Intensive Care Medicine,Emergency Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3