A Prospective Comparison of 180 Versus 360-Degree Gonioscopy-Assisted Transluminal Trabeculotomy Outcomes in Pseudoexfoliation Glaucoma

Author:

Gunay Murat,Cigiltepe Irem Berfu,Turk Adem,Uzlu Dilek,Kose Busra

Abstract

Précis: Analysis of surgical success and intraocular pressure (IOP), best-corrected visual acuity (BCVA), and antiglaucomatous medication (AGM) changes between segmental 180-degree and 360-degree gonioscopy-assisted transluminal trabeculectomy (GATT) in patients with pseudoexfoliation glaucoma (PEXG) showed no significant difference. Objective: To compare surgical outcomes of segmental 180-degree and 360-degree GATT in patients with PEXG. Materials and Methods: Prospective, comparative study of 65 PEXG eyes, who underwent segmental 180-degree GATT (GATT 180-degree group, 31 eyes) and 360-degree GATT (GATT 360-degree group, 34 eyes) in a tertiary academic center over a 12-month of follow-up. Primary outcome was qualified and complete surgical success rates for criterion A (IOP <18 mm Hg and >30% reduction) and criterion B (IOP <15 mm Hg and >30% reduction). Secondary outcome measures included IOP reduction, BCVA change, AGM use, and postoperative complications. Results: The probabilities of qualified and complete success rates both for criteria A and B did not significantly differ between the groups (P > 0.05). IOP and BCVA levels were similar at each time point (P > 0.05). IOP reduction was 59.3 ± 9.5% in the GATT 180-degree group and 55.8 ± 18.1% in the GATT 360-degree group (P = 0.33). No significant difference in the mean number of AGM was present at the 12-month visit (1.2 ± 1.1 in GATT 180-degree group vs 1.5 ± 1.2 in GATT 360-degree group, P = 0.25). Significantly higher incidences of postoperative hyphema and IOP spikes were observed in the GATT 360-degree group (P = 0.01 and P = 0.008, respectively). Conclusion: Both segmental 180-degree and 360-degree GATT similarly reduced IOP and AGM with comparable surgical success rates in patients with PEXG at the end of 12 months. Postoperative hyphema and IOP spike rates were significantly higher after 360-degree GATT. Segmental 180-degree GATT may be sufficient to adequately modulate IOP with a lower incidence of postoperative complications in PEXG.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Reference27 articles.

1. Microinvasive glaucoma surgery: an evidence-based review;Birnbaum;Semin Ophthalmol,2021

2. Gonioscopy-assisted transluminal trabeculotomy, ab interno trabeculotomy: technique report and preliminary results;Grover;Ophthalmology,2014

3. Exfoliation syndrome;Ritch;Surv Ophthalmol,2001

4. Trabecular meshwork in pseudoexfoliation syndrome with and without open-angle glaucoma. A morphometric, ultrastructural study;Schlötzer-Schrehardt;Invest Ophthalmol Vis Sci,1995

5. Mechanisms of glaucoma in exfoliation syndrome;Ozaki;J Glaucoma,2018

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3