Gastric Volume and Antral Area in the Fasting State: A Meta-analysis of Individual Patient Data

Author:

Perlas Anahi1ORCID,Arzola Cristian2,Portela Natalia3,Mitsakakis Nicholas4,Hayawi Lamia5,Van de Putte Peter6

Affiliation:

1. 1Toronto Western Hospital, University Health Network, Department of Anesthesiology and Pain Medicine, University of Toronto, Toronto, Canada.

2. 2Sinai Health System, Department of Anesthesiology and Pain Medicine, University of Toronto, Toronto, Canada.

3. 3Mount Sinai hospital, Sinai Health System, Department of Anesthesiology and Pain Medicine, University of Toronto, Toronto, Canada.

4. 4Clinical Research Unit, Children’s Hospital of Eastern Ontario Research Institute, Ottawa, Canada.

5. 5Clinical Research Unit, Children’s Hospital of Eastern Ontario Research Institute, Ottawa, Canada.

6. 6Imelda Vzw (Non-profit Organization), Bonheiden, Belgium.

Abstract

Background Pulmonary aspiration of gastric content is a serious anesthetic complication. Gastric point-of-care ultrasound can determine the type and volume of gastric content when clinical information is equivocal. However, a cutoff value of either antral cross-sectional area or volume that may be considered as the upper limit of normal in fasting subjects is still controversial. The aim of this study is to characterize the distribution of baseline antral area and volume in fasting adult subjects and to identify an upper limit (95th percentile) of these distributions. Methods The authors conducted a meta-analysis of individual participant data of primary studies from an academic research network of investigators collaborating in gastric ultrasound. Studies between January 2009 and December 2020 were included. Results Twelve primary studies met inclusion criteria and were included in the analysis with a sample size of 1,203 subjects. The 95th percentile of area values (measured in the right lateral decubitus) was 9.9 cm2 (95% CI, 9.4 to 10.4), and of volume, 2.3 ml/kg (95% CI, 2.3 to 2.4). In addition, an antrum grade 0 or 1 indicates a 98% probability of an antral area below the 95th percentile. Conclusions An area of 10 cm2 measured in the right lateral decubitus could be a simple, data-driven upper limit of antral area that could serve as a surrogate of upper limit of normal gastric volume values in fasting adults. These results are limited by the highly selected sampling of the studies included. Editor’s Perspective What We Already Know about This Topic What This Article Tells Us That Is New

Publisher

Ovid Technologies (Wolters Kluwer Health)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3