Assisted Fluid Management Software Guidance for Intraoperative Fluid Administration

Author:

Maheshwari Kamal,Malhotra Gaurav,Bao Xiaodong,Lahsaei Peiman,Hand William R.,Fleming Neal W.,Ramsingh Davinder,Treggiari Miriam M.,Sessler Daniel I.,Miller Timothy E.,

Abstract

Background Excessive or inadequate fluid administration causes complications, but despite this, fluid administration during noncardiac surgery is highly variable. Goal-directed management helps optimize the amount and timing of fluid administration; however, implementation is difficult because algorithms are complex. The authors therefore tested the performance of the Acumen Assisted Fluid Management software (Edwards Lifesciences, USA), which is designed to guide optimal intravenous fluid administration during surgery. Methods In this multicenter, prospective, single-arm cohort evaluation, the authors enrolled 330 adults scheduled for moderate- to high-risk noncardiac surgery that required arterial catheter insertion and mechanical ventilation. Clinicians chose a fluid strategy based on a desired 10%, 15%, or 20% increase in stroke volume (SV) in response to a fluid bolus. Dedicated fluid management software prompted “test” or “recommended” boluses, and clinicians were free to initiate a “user” bolus of 100 to 500 ml of crystalloid or colloid. Clinicians were free to accept or decline the software prompts. The authors primarily compared the fraction of software-recommended boluses that produced suitable increases in SV to a 30% reference rate. On an exploratory basis, we compared responses to software-recommended and clinician-initiated boluses. Results Four hundred twenty-four of 479 (89%) software-recommended fluid boluses and 508 of 592 (86%) clinician-initiated fluid boluses were analyzed per protocol. Of those, 66% (95% CI, 62 to 70%) of delivered fluid boluses recommended by the software resulted in desired increases in SV, compared with the 30% reference rate, whereas only 41% (95% CI, 38 to 44%) of clinician-initiated boluses did (P < 0.0001). The mean ± SD increase in SV after boluses recommended by the software was 14.2 ± 13.9% versus 8.3 ± 12.1% (P < 0.0001) for those initiated by clinicians. Conclusions Fluid boluses recommended by the software resulted in desired SV increases more often, and with greater absolute SV increase, than clinician-initiated boluses. Automated assessment of fluid responsiveness may help clinicians optimize intraoperative fluid management during noncardiac surgery. Editor’s Perspective What We Already Know about This Topic What This Article Tells Us That Is New

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Cited by 13 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3