Endoscopic Ultrasound-based Shear Wave Elastography for Detection of Advanced Liver Disease

Author:

AbiMansour Jad1,Chin Jerry Yung-Lun1,Kaur Jyotroop1,Vargas Eric J.1,Abu Dayyeh Barham K.1,Law Ryan1,Garimella Vishal1,Levy Michael J.1,Storm Andrew C.1,Dierkhising Ross2,Allen Alina1,Venkatesh Sudhakar3,Chandrasekhara Vinay1

Affiliation:

1. Division of Gastroenterology and Hepatology, Department of Internal Medicine, Department of Internal Medicine

2. Department of Quantitative Health Sciences, Division of Clinical Trials and Biostatistics

3. Department of Radiology, Mayo Clinic, Rochester, MN

Abstract

Background and Aims: Endoscopic ultrasound shear wave elastography (EUS-SWE) is a novel modality for liver stiffness measurement. The aims of this study are to evaluate the performance and reliability of EUS-SWE for detecting advanced liver disease in a prospective cohort. Methods: EUS-SWE measurements were prospectively obtained from patients undergoing EUS between August 2020 and March 2023. Liver stiffness measurements were compared between patients with and without advanced liver disease (ALD), defined as stage ≥3, to determine diagnostic accuracy for advanced fibrosis and portal hypertension. Logistic regression was performed to identify variables that impact the reliability of EUS-SWE readings. Select patients underwent paired magnetic resonance elastography (MRE) for liver fibrosis correlation. Results: Patients with ALD demonstrated higher liver stiffness compared to healthy controls (left lobe: 17.6 vs. 12.7 kPa, P<0.001; median right lobe: 24.8 vs. 11.0 kPa, P<0.001). The area under the receiver operator characteristic (AUROC) for the detection of ALD was 0.73 and 0.80 for left and right lobe measurements, respectively. General anesthesia was associated with reliable EUS-SWE liver readings (odds ratio: 2.73, 95% CI: 1.07-7.39, P=0.040). Left lobe measurements correlated significantly with MRE with an increase of 0.11 kPa (95% CI: 0.05-0.17 kPA) for every 1 kPa increase on EUS-SWE. D. Conclusions: SWE is a promising technology that can readily be incorporated into standard EUS examinations for the assessment of ALD.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3