Reliable Long-Term Serial Evaluation of Cochlear Function Using Pulsed Distortion-Product Otoacoustic Emissions: Analyzing Levels and Pressure Time Courses

Author:

Bader Katharina1,Dalhoff Ernst2,Dierkes Linda1,Braun Lore Helene3,Gummer Anthony W.2,Zelle Dennis24

Affiliation:

1. Department of Otolaryngology, Head and Neck Surgery, Eberhard-Karls-University Tübingen, Tübingen, Germany

2. Section of Physiological Acoustics and Communication, Department of Otolaryngology, Eberhard-Karls-University Tübingen, Tübingen, Germany

3. Department of Radiooncology, Eberhard-Karls-University Tübingen, Tübingen, Germany

4. Earlab GmbH, Tübingen, Germany.

Abstract

Objectives: To date, there is no international standard on how to use distortion-product otoacoustic emissions (DPOAEs) in serial measurements to accurately detect changes in the function of the cochlear amplifier due, for example, to ototoxic therapies, occupational noise, or the development of regenerative therapies. The use of clinically established standard DPOAE protocols for serial monitoring programs appears to be hampered by multiple factors, including probe placement and calibration effects, signal-processing complexities associated with multiple sites of emission generation as well as suboptimal selection of stimulus parameters. Design: Pulsed DPOAEs were measured seven times within 3 months for f 2 = 1 to 14 kHz and L 2 = 25 to 80 dB SPL in 20 ears of 10 healthy participants with normal hearing (mean age = 32.1 ± 9.7 years). L 1 values were computed from individual optimal-path parameters derived from the corresponding individual DPOAE level map in the first test session. Three different DPOAE metrics for evaluating the functional state of the cochlear amplifier were investigated with respect to their test-retest reliability: (1) the interference-free, nonlinear-distortion component level (L OD), (2) the time course of the DPOAE-envelope levels, L DP(t), and (3) the squared, zero-lag correlation coefficient ( ) between the time courses of the DPOAE-envelope pressures, p DP(t), measured in two sessions. The latter two metrics include the two main DPOAE components and their state of interference. Results: Collated over all sessions and frequencies, the median absolute difference for L OD was 1.93 dB and for L DP(t) was 2.52 dB; the median of was 0.988. For the low (f 2 = 1 to 3 kHz), mid (f 2 = 4 to 9 kHz), and high (f 2 = 10 to 14 kHz) frequency ranges, the test-retest reliability of L OD increased with increasing signal to noise ratio (SNR). Conclusions: On the basis of the knowledge gained from this study on the test-retest reliability of pulsed DPOAE signals and the current literature, we propose a DPOAE protocol for future serial monitoring applications that takes into account the following factors: (1) separation of DPOAE components, (2) use of individually optimal stimulus parameters, (3) SNR of at least 15 dB, (4) accurate pressure calibration, (5) consideration of frequency- and level-dependent test-retest reliabilities and corresponding reference ranges, and (6) stimulus levels L 2 that are as low as possible with sufficient SNR to capture the nonlinear functional state of the cochlear amplifier operating at its highest gain.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3