Quantification of vessel separation using the carotid-jugular angle to predict the nerve origin of neck peripheral nerve sheath tumours: a pooled analysis of cases from the literature and a single-center cohort

Author:

Wong Chia-En1ORCID,Huang Chi-Chen1,Chuang Ming-Tsung2ORCID,Lee Po-Hsuan1ORCID,Chen Liang-Yi1,Hsu Hao-Hsiang1,Huang Chih-Yuan1,Wang Liang-Chao1ORCID,Lee Jung-Shun134ORCID

Affiliation:

1. Section of Neurosurgery, Department of Surgery, National Cheng Kung University Hospital

2. Medical Imaging

3. Cell Biology and Anatomy

4. Institute of Basic Medical Sciences, College of Medicine, National Cheng Kung University, Tainan, Taiwan

Abstract

Background: Postoperative nerve palsy is a major complication following resection of neck peripheral nerve sheath tumours (PNSTs). Accurate preoperative identification of the nerve origin (NO) can improve surgical outcomes and patient counselling. Material and methods: This study was a retrospective cohort and quantitative analysis of the literature. The authors introduced a parameter, the carotid-jugular angle (CJA), to differentiate the NO. A literature review of neck PNST cases from 2010 to 2022 was conducted. The CJA was measured from eligible imaging data, and quantitative analysis was performed to evaluate the ability of the CJA to predict the NO. External validation was performed using a single-centre cohort from 2008 to 2021. Results: In total, 17 patients from our single-centre cohort and 88 patients from the literature were analyzed. Among them, 53, 45, and 7 patients had sympathetic, vagus, and cervical nerve PNSTs, respectively. Vagus nerve tumours had the largest CJA, followed by sympathetic tumours, whereas cervical nerve tumours had the smallest CJA (P<0.001). Multivariate logistic regression identified a larger CJA as a predictor of vagus NO (P<0.001), and receiver operating characteristic (ROC) analysis showed an area under the curve (AUC) of 0.907 (0.831–0.951) for the CJA to predict vagus NO (P<0.001). External validation showed an AUC of 0.928 (0.727–0.988) (P<0.001). Compared with the AUC of the previously proposed qualitative method (AUC=0.764, 0.673–0.839), that of the CJA was greater (P=0.011). The cut-off value identified to predict vagus NO was greater than or equal to 100°. Receiver operating characteristic analysis showed an AUC of 0.909 (0.837–0.956) for the CJA to predict cervical NO (P<0.001), with a cut-off value less than 38.5°. Conclusions: A CJA greater than or equal to 100° predicted a vagus NO and a CJA less than 100° predicted a non-vagus NO. Moreover, a CJA less than 38.5 was associated with an increased likelihood of cervical NO.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

General Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3