Off-Pump Positioning of a Conventional Aortic Valve Prosthesis through the Left Ventricular Apex with the Universal Cardiac Introducer under Sole Ultrasound Guidance, in the Pig

Author:

Guiraudon Gerard M.12,Jones Douglas L.1234,Bainbridge Daniel5,Peters Terence M.126

Affiliation:

1. Canadian Surgical Technologies and Advance Robotics, Lawson Health Research Institute, London, Ontario, Canada

2. Imaging Group, Robarts Research Institute, London, Ontario, Canada;

3. Departments of Physiology and Pharmacology

4. Departments of Medicine

5. Departments of Anaesthesia

6. Medical Biophysics, the University of Western Ontario, and the London Health Science Center, London, Ontario, Canada.

Abstract

Objective To test an alternative to catheter and open-heart techniques, by documenting the feasibility of implanting an unmodified mechanical aortic valve (AoV) in the off pump, beating heart using the universal cardiac introducer (UCI) attached to the left ventricular (LV) apex. Methods In six pigs, the LV apex was exposed by a median sternotomy. The UCI was attached to the apex. A 12-mm punching tool (punch), introduced through the UCI, was used to create a cylindrical opening through the apex. Then, the AoV, secured to a holder, was introduced into the LV, using transesophageal echocardiographic, guided through the apical LV opening, navigated into the LV outflow tract, and positioned within the aortic annulus. Trans-esophageal echocardiographic guidance was useful for navigation and positioning by superimposing the aortic annulus and prosthetic ring while Doppler imaging verified preserved prosthetic function and absence of perivalvular leaks. The valve function and hemodynamics were observed before termination for macroscopic evaluation. Results The punch produced a clean opening without fragmentation or myocardial embolization. During advancement of the mechanical AoV, there were no arrhythmias, mitral valve dysfunctions, evidence of myocardial ischemia, or hemodynamic instability. The AoVs were well seated over the annulus, without obstructing the coronaries or contact with the conduction system. The ring of AoVs was well circumscribed by the aortic annulus. Conclusions This study documented the feasibility of positioning a mechanical AoV on the closed, beating heart. These results should encourage the development of adjunct technologies to deliver current tissue or mechanical AoV with minimal side effects.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Surgery,Pulmonary and Respiratory Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. The Use of Ultrasound to Guide Interventions: From Bench to Bedside and Back Again;Seminars in Cardiothoracic and Vascular Anesthesia;2010-08-12

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3