Devices for Lung Isolation Used by Anesthesiologists with Limited Thoracic Experience

Author:

Campos Javier H.1,Hallam Ezra A.2,Van Natta Timothy3,Kernstine Kemp H.4

Affiliation:

1. Vice Chair of Clinical Affairs and Director of Cardiothoracic Anesthesia, Professor of Anesthesia, Department of Anesthesia, The University of Iowa Roy J. and Lucille A. Carver College of Medicine.

2. Medical Student, Roy J. and Lucille A. Carver College of Medicine, The University of Iowa.

3. Assistant Professor of Surgery, Division of Cardiothoracic Surgery, Department of Surgery, University of Iowa Health Care.

4. Professor of Surgery, Director, Department of Thoracic Surgery, City of Hope National Medical Center, Duarte, California.

Abstract

Background Lung isolation is accomplished with a double-lumen tube or a bronchial blocker. Previous studies comparing lung isolation methods were performed by experienced anesthesiologists in thoracic anesthesia. Therefore, the results of these studies may not be relevant to the anesthesiologist with limited experience. This study compared the success rates of lung isolation devices among anesthesiologists with limited experience in thoracic anesthesia. Methods A prospective, randomized trial was designed to determine the success and time required for proper placement of the left-sided double-lumen tube (n = 22), the Univent tube (Vitaid Ltd., Lewiston, NY; n = 22), and the Arndt Blocker (Cook Critical Care, Bloomington, IN; n = 22). Anesthesiologists with less than two lung isolation cases per month were included (faculty n = 17 and senior residents n = 11). Variables recorded included (1) successful placement (as determined by an independent observer), (2) time of placement, and (3) the number of times the fiberoptic bronchoscope was used. Results Participants failed to place or position their assigned device in 25 of 66 patients (failure was 39% among faculty and 36% among senior residents). The failure rate did not differ among the three devices (P = 0.65). The median (25th-75th percentile) times to complete the placement procedures were as follows: (1) double-lumen tube: 6.1 min (4.6-9.5 min), (2) Univent tube: 6.7 min (4.9-8.8 min), and (3) Arndt Blocker: 8.6 min (5.8-17.5 min) (P = 0.45 comparing all devices). After device malposition was identified, it took 1 min or less for the investigating anesthesiologist to achieve optimal position. Conclusions Anesthesiologists with limited experience in thoracic anesthesia frequently fail to successfully place lung isolation devices. Rapid successful device placement by an experienced anesthesiologist excluded any contribution of uniquely difficult anatomy. The nature of the malpositions suggests that the most critical factor in successful placement was the anesthesiologist's knowledge of endoscopic bronchial anatomy.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference17 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3